SCF-6 Canister and Inline Splice Closures
Page 10
SRP 003-485 • Issue 6 • October 2006
Figure 3 — Sheath Removal Lengths
For endspan or drop cable applications
, remove indicated length of cable sheath
and armor (where applicable) as shown in Figure 3 according to cable
manufacturer’s instructions.
Aramid Yarn and
Central Member
15 cm (6 in.)
Buffer tubes
Bare fibers
133 cm (52 in.)
254 cm (100 in.)
Aramid Yarn and
Central Member
15 cm (6 in.)
Buffer tubes
Bare fibers
102 cm (41 in.)
226 cm (89 in.)
Aramid Yarn and
Central Member
15 cm (6 in.)
Aramid Yarn and
Central Member
15 cm (6 in.)
Bare fibers
Bare fibers
Buffer tubes
Buffer tubes
56 cm (22 in.)
75 cm (30 in.)
198 cm (78 in.)
251 cm (99 in.)
SCF-6T40
SCF-6T30
First End Cap (Attached to Frame Assembly)
Opposite End Cap (Attached to U-Bar)
First End Cap (Attached to Frame Assembly)
Opposite End Cap (Attached to U-Bar)
Aramid Yarn and
Central Member
15 cm (6 in.)
Buffer tubes
Bare fibers
56 cm (22 in.)
198 cm (78 in.)
SCF-6C22 (endspan)
Aramid Yarn and
Central Member
15 cm (6 in.)
Buffer tubes
Bare fibers
75 cm (30 in.)
251 cm (99 in.)
SCF-6C28 (endspan)
KPA-0501
Step 2
Cut the central member of each cable to 15 cm (approximately 6 inches) from the
sheath using side cutters.
Step 3
If aramid yarn is present, leave 15 cm (approximately 6 inches) of yarn for
additional strain-relieving.