12. Installing Splitter Modules
Refer to the routing label on the
inside of the enclosure door for
a description of the enclosure
layout and installation sequence
for the enclosure size into which
you are installing modules.
Splitter modules are installed
into the splitter storage area.
Preconnectorized output fibers
from the splitter modules can
be mated in the distribution field
or routed to and stored in the
connector parking field for mating
later.
Step 1:
Remove splitter
modules from their
packaging.
Step 2:
Open splitter area
cover; install the
module in the first
vacant slot. Install
the modules in the
enclosure in the
order shown by the
schematic label on the
inside of the enclosure
door.
Step 3:
Secure the splitter
module in the splitter
storage area with the
retention screw. When
installing modules into the 432-fiber enclosure, note that the installation sequence is
different for 1x32 modules than for dual 1x16 modules.
13. Connecting Splitter Input Fibers to Feeder Cable
The splitter module is designed with bend-optimized fiber. Do not uncoil the slack of the input
fiber, except when necessary to reach the appropriate feeder port.
WARNING: Never look directly into the end of a fiber that may be carrying laser light.
Laser light can be invisible and can damage your eyes. Viewing it directly does not cause pain.
The iris of the eye will not close involuntarily as when viewing a bright light. Consequently,
serious damage to the retina of the eye is possible. Should accidental eye exposure to laser
light be suspected, arrange for an eye examination immediately.
WARNING:
This product is designed to meet specifications for Class 3 lasers only and should
not be used with optical fiber transmission systems containing lasers of classes for which they
have not been certified. DO NOT use magnifiers in the presence of laser radiation. Diffused
laser light can cause eye damage if focused with optical instruments. Should accidental eye
exposure be suspected, arrange for an eye examination immediately.
432-fiber Cabinet Module Installation Schematic