STANDARD RECOMMENDED PROCEDURE 003-737 | ISSUE 4 | MAy 2015 | PAGE 10 OF 25
7. Accessing the Enclosure
If the enclosure door is closed, use a
216B tool or a 7/16-in nutdriver on the
latch to open it as shown by the inset in
Figure 10. To facilitate work operations
inside the enclosure, the exterior door
may be removed.
Step 1:
Remove ground strap at
the bottom of the door
by removing the two nuts
securing the ground lug to
the door. Replace the two
nuts on the stud to prevent
misplacing them during the
rest of the work operations.
Step 2:
After removing the ground
strap, lift the door free of the
hinges. Set the door aside.
Step 3:
When work operations are
complete, reverse these
steps to replace the door
and ground strap.
8. Grounding the Enclosure
Step 1:
Open the panel door (Figure 11) inside the enclosure to access the ground bar in the
upper right side of the enclosure.
Step 2:
Open the splice housing door and pedestal skirt
door, if the enclosure is equipped with these
items. Bring the ground cable up through the
KPA-0739
Remove Strap
1
Unlock Door
2
3
Lift Door
Off Hinges
Figure 10
KPA-0699
OPEN
OPEN
Open
Closed
Figure 11
KPA-0734
Figure 12