STANDARD RECOMMENDED PROCEDURE 003-737 | ISSUE 4 | MAy 2015 | PAGE 17 OF 25

10.2.2  Install Grounding Hardware to Armored Cable

Step 1: 

Cut a slit into opposite sides of the outer sheath 

and armor about 5 cm (2 in) from the end of the 

sheath (Figure 3). To do this, score the armor 

with a cable knife (being careful not to damage 

the inner sheath) and split the sheath by flexing 

it.

Step 2: 

Position the grounding clamp base plate under 

the armor with the stops on the clamp butted 

against the outside of the armor and sheath. Tap 

the sheath above the ground clamp base to set 

the teeth.

IMPORTANT: 

When the cable has metallic strength members, 

attach the extension bracket as shown in the inset 

(p/n UCN-GND-SC20, purchased separately) to the 

base plate before installing the top plate.

Step 3: 

Position the top plate and lock nut on the outer 

sheath over the base plate. Tighten nut to a 

torque value of 23 in-lb using a 3/8-in wrench 

to drive the teeth on the upper plate into the 

sheath.

Step 4: 

Wrap the grounding connector and split portion 

of the sheath with a few wraps of vinyl tape.

Step 5: 

Attach the ring terminal of the ground wire over 

the top plate. Add a lock nut and tighten to a 

torque value of 23 in-lb (Figure 23).

10.2.3  Secure Metallic Strength Members

Figure 23

Step 1: 

Bend metallic strength members over the slots in the extension bracket as shown in 

the inset in (Figure 24) and then trim excess strength member.

Step 2: 

Wrap the yarn, if present, twice in a clockwise direction around the threaded stud.

Step 3: 

Install restraint cap from the strain-relief kit as shown in Figure 24.

Step 4: 

Install a washer and nut and tighten securely.

Step 5: 

Repeat for other cables, when applicable.

IMPORTANT: 

Confirm all buffer tubes are clear of the strength elements prior to securing the restraint 

cap.

Figure 24

1

2

3

4

5 cm (2 in)

1

Stop

Base Plate

2

6 cm (2.4 in)

5

3

Extension

Bracket

Top Plate

4

Extension bracket not shown.

Extension bracket not shown.

KPA-0019

Yarn, if present

Metallic 

strength 

members

Restraint cap

KPA-0899

Содержание OptiTect EVO-707-EN

Страница 1: ...the Enclosure into a Rack 8 6 3 Mount the Enclosure on the Floor 8 7 Accessing the Enclosure 10 8 Grounding the Enclosure 10 9 Managing Fiber 11 9 1 Field installed Unconnectorized Feeder and Distribu...

Страница 2: ...The door can be locked with a 216B tool and padlock The standard configuration is one connectorized distribution and one connectorized feeder cable preinstalled and attached to the internal housings 1...

Страница 3: ...nd 10 in on each side of the enclosure to enable the door to open fully The installing company should obtain rights of way from property owners and permits or other approvals from public authorities p...

Страница 4: ...urations required for your application the following tools may be required to install the enclosure Drill and drill bits Lint free wipes Appropriate hardware if wall mounting for the wall mount surfac...

Страница 5: ...er and distribution cable strain relief kit Additional Container Contents for Field splice Applications Splice trays number of trays included depends upon configuration Figure 2 Cable Entry Ports Slac...

Страница 6: ...t the stabilizers are extended and firmly positioned before Lifting Avoid overhead obstructions or power lines when lifting WARNING The enclosure is heavy and requires two people to maneuver it Observ...

Страница 7: ...in above the floor Ensure the bracket is level and secured to the wall to support the weight of the enclosure Step 3 Attach the wallmount mounting brackets to the rear of the enclosure as shown in Fig...

Страница 8: ...lation pad installed between pedestal base and floor 1 Ground wire Step 1 Determine the cabinet location in your application per the installation plan Step 2 Determine the type of installation for flo...

Страница 9: ...re for your application Step 6 Assemble the cabinet to the pedestal by fully securing the four 10 washers and self locking nuts provided Step 7 Reattach the front access panel Step 8 Replace grounding...

Страница 10: ...misplacing them during the rest of the work operations Step 2 After removing the ground strap lift the door free of the hinges Set the door aside Step 3 When work operations are complete reverse these...

Страница 11: ...adapter fields 9 2 Preinstalled Connectorized Feeder And Distribution Cable Option When the enclosure is ordered with the fully connectorized cable configuration the Feeder cable F1 will be mated in t...

Страница 12: ...pre routed at the factory and stored for splicing 10 1 Feed Cable into Enclosure CAUTION Fiber optic cable is sensitive to excessive pulling bending and crushing forces Consult the cable specificatio...

Страница 13: ...rovided with the cable Enclosure Capacity Distribution Cable s F2 Feeder Cable s F1 144 fibers 9 5 feet 10 5 feet 288 fibers 10 feet 11 feet 432 fibers 10 5 feet 11 5 feet Table 2 Cable Sheath Removal...

Страница 14: ...h of Braided Tubes Required Figure 15 A B C F1 A B C F2 KPA 0897 Route large diameter cable as shown Route smaller diameter cables as shown OR C B Top View of Splice Compartment B D Top of Cabinet 1 5...

Страница 15: ...ied in the braided tubing kit to the end of the fiber s with the electrical tape Figure 16 Figure 16 Step 3 Push the braided tubing over the rod Figure 17 Figure 17 Step 4 Slide tubing toward the cabl...

Страница 16: ...Figure 21 Step 8 Secure the other end of the braided tubing Figure 22 Cut off the plastic rod Wrap electrical tape around the end of the braided tubing IMPORTANT Approximately 48 in of ribbon matrix s...

Страница 17: ...8 in wrench to drive the teeth on the upper plate into the sheath Step 4 Wrap the grounding connector and split portion of the sheath with a few wraps of vinyl tape Step 5 Attach the ring terminal of...

Страница 18: ...event the retention grip from overlapping the ground hardware Step 2 If there is a central member present install the central member restraint clip as shown in Figure 25 Trim the central member flush...

Страница 19: ...curs in the bottom splice tray in the splice housing with Distribution splicing in subsequent trays above Two sub units jacketed or braided tubing with three 12 fiber ribbons per sub unit can be strai...

Страница 20: ...the connectorized pigtails to the Feeder or Distribution cable in accordance with the instructions provided with the splicing equipment Step 5 Return and route the fibers within the splice tray securi...

Страница 21: ...13 Connecting Splitter Input Fibers to Feeder Cable The splitter module is designed with bend optimized fiber Do not uncoil the slack of the input fiber except when necessary to reach the appropriate...

Страница 22: ...is application making connections with the feeder power on may destroy the connector Step 3 Route the connectorized splitter input fiber to the appropriate feeder port Figure 33 Figure 33 Step 4 Remov...

Страница 23: ...e using a dry process Mate the splitter output fiber connector to the distribution connector Step 4 Route the splitter output fiber slack as shown on the fiber routing label on the inside of the enclo...

Страница 24: ...rule twice with a lint free wiping material moistened with isopropyl alcohol Then wipe across the end of the ferrule Step 3 Repeat previous step with a dry wipe If necessary it is also possible to acc...

Страница 25: ...do not exceed the minimum bend radius Check cables for unnecessary strain for crimping or crushing at entries and exits and for damage Check unit record labels to make sure all are clear and accurate...

Отзывы: