CONCENTRATE HANDLING & LOADING
It is recommended that the concentrate be thawed in a refrigerated 35
°
F-40
°
F (1.6
°
C-4.4
°
C) compartment for a
minimum of 48 hours prior to loading into the Quest Juice Dispenser.
!
WARNING:
Concentrate must be completely thawed and within the temperature range of 35
°
F-40
°
F (1.6
°
C-4.4
°
C) prior to
loading. Failing to supply concentrate inside the recommended temperature range, especially below 35
°
F (1.6
°
C), will
cause an out of brix drink (refer to the Brixing Procedure section for details).
L
OADING
C
ONCENTRATE
The Quest Juice Dispenser is designed to use either disposable juice concentrate containers or
the optional Cornelius generic refillable container sold separately.
1.
Thoroughly shake concentrate, for a minimum of 30 seconds, prior to use.
2.
Place concentrate containers on the dispensing platform shelf inside the refrigerated cabinet.
3.
Engage the concentrate container by pressing it downward into the bottle adapter opening
on the dispensing platform.
NOTE: Be sure to lubricate the o-ring seal on the container nozzle. This will ensure a
good seal and allow the pumps to draw concentrated from the containers more easily. Failure
to create a good seal at this connection may result in weak drinks and/or seepage of concen-
trate.
4.
Prime each pump by closing the cabinet door and press each dispense button until concentrate flows from the
dispense nozzles.
C
HANGING
C
ONCENTRATE
C
ONTAINERS
:
1.
Open the cabinet door and move the valve handle from “Dispense” to “Flush”
2.
Close the door. Depress and hold the dispense button until clear water flows from the dispense nozzle.
3.
Open the cabinet door and return the handle to “Dispense”.
4.
Depress and hold the dispense button for 1-2 seconds. This will relieve water pressure from the concentrate
pump system.
5.
Load concentrate container (see
Loading Concentrate
).
C
HANGING
C
ONCENTRATE
C
ONTAINERS
FOR
M
ODELS
WITHOUT
F
LUSH
/D
ISPENSE
O
PTION
:
1.
Fill a clean concentrate container with water and load inside cabinet.
2.
Close the door. Depress and hold the dispense button until clear water flows from the dispense nozzle.
3.
Remove the container of water from the cabinet.
4.
Depress and hold the dispense button for 1-2 seconds. This will relieve water pressure from the concentrate
pump system.
5.
Load concentrate container (see
Loading Concentrate
).