Quest Service Manual
© 2004-2014, Cornelius Inc.
- 9 -
Publication Number: 720901117SER
S
EMI
-A
NNUAL
CAUTION:
!
The following procedures require removal of the dispenser side panel(s). Disconnect the power cord from the
receptacle prior to proceeding.
Clean Water Inlet Strainer:
1.
Remove the right side panel from the dispenser.
2.
Turn off the water supply to the dispenser.
3.
Remove the access port from the “Y” shaped water inlet solenoid located on the
right side of the dispenser.
4.
Clean and reinstall the stainless steel water strainer.
Clean Chassis Interior:
1.
Clean the condenser cooling fins.
2.
Clean the air inlet grilles located on the rear and top panels of the dispenser.
3.
Clean the interior base.
4.
Wipe the fan blade clean.
5.
Reinstall the right side panel, turn on the water supply, and plug the dispenser into the power receptacle.
Check and Top-Off Water Ice Bath:
1.
Remove the drip tray and lower splash panel.
2.
If the Ice bath level is below the “Full” indicator, top it off with water. Refer to the Filling the Ice Bath procedure in
the Installation section of this manual.