Non-Carbonated Impulse Installation & Operations Manual
© 2003, IMI Cornelius Inc.
- 5 -
Publication Number: 859000159INS
Adjusting Flow Rates
Flow rates of the water and concentrate are adjusted based on the desired ratio. For example: if the
desired ratio is 5:1, then the flow rate of the water is 5 times that of the concentrate.
If the desired finished drink flow rate is 3.0 ounces per second, then the water flow rate is 2.5 oz./sec.
and the concentrate flow rate is 0.5 oz./sec. (The water at 2.5 oz./sec. is five times the 0.5 oz./sec. con-
centrate flow rate.)
Flow Rates oz./sec. Based on 5:1 Ratio
Finished Drink oz./sec.
Water oz./sec.
Concentrate oz./
sec.
1.5
1.25
.25
2.0
1.67
.33
2.5
2.08
.42
3.0
2.5
.50
3.5
2.92
.58
4.0
3.33
.67
4.5
3.75
.75