background image

Non-Carbonated Impulse Installation & Operations Manual

© 2003, IMI Cornelius Inc.

- 1 -

Publication Number: 859000159INS

SAFETY

A

UTHORIZED

 S

ERVICE

 P

ERSONNEL

CAUTION

 — Only trained and certified electrical, plumbing and refrigeration techni-

cians should service this unit. ALL WIRING AND PLUMBING MUST CONFORM TO 
NATIONAL AND LOCAL CODES.

CO

2

 (C

ARBON

 D

IOXIDE

) W

ARNING

WARNING

 — CO

2

 Displaces Oxygen. Strict Attention must

 

be observed in the pre-

vention of CO

2

 gas leaks in the entire CO

2

 and soft drink system. If a CO

2

 gas leak is 

suspected, particularly in a small area, immediately ventilate the contaminated area 
before attempting to repair the leak. Personnel exposed to high concentration of CO

2

 

gas will experience tremors which are followed rapidly by loss of consciousness and death.

SYSTEM DIMENSIONS

Impulse 1 Unit

Height

27 inches

Width

16 inches

Depth 

26 7/8 inches

Shipping Weight 

(approx.)

120 pounds

R

ECOGNIZE

 

SAFETY

 

ALERTS

This is the safety alert symbol. When you see it in this manual or on the 

Содержание Impulse Non-Carbonated Post-Mi

Страница 1: ...IMPULSE Non Carbonated Post Mix Beverage Dispenser Installation Operation Manual Release Date December 16 2003 Publication Number 859000159INS Revision Date NA Revision A www cornelius com...

Страница 2: ...quipment Appropriate safety precautions should be followed and all local safety and construction requirements should be met To inquire about current revisions of this and other documentation or for as...

Страница 3: ...mmary 2 Electrical Requirements 2 Installation Procedure 2 Counter top Installation 2 Connect Concentrate and Water Lines 4 Adjust Water To Concentrate Ratio 4 Adjusting Flow Rates 5 OPERATIONS 6 Oper...

Страница 4: ...Impulse Installation and Operation Manual Publication Number 859000159INS ii 2003 IMI Cornelius Inc...

Страница 5: ...ion must be observed in the pre vention of CO2 gas leaks in the entire CO2 and soft drink system If a CO2 gas leak is suspected particularly in a small area immediately ventilate the contaminated area...

Страница 6: ...nt or rear counter must be level and able to support 400 lbs Environment indoor installation only Temperature 40 to 110 F ambient temperature Clearance 18 inches above 6 inches on sides and rear CO2 7...

Страница 7: ...th with clean water until it comes out the overflow tube Make sure the overflow tube is not blocked or plugged Use low mineral tap water not distilled or deionized water NOTE Water bath must be filled...

Страница 8: ...equired If water supply pressure to the unit is more than 50 psi a water pressure regulator must be installed in the supply line NOTE A water shutoff valve and water filter in the water supply line ar...

Страница 9: ...he flow rate of the water is 5 times that of the concentrate If the desired finished drink flow rate is 3 0 ounces per second then the water flow rate is 2 5 oz sec and the concentrate flow rate is 0...

Страница 10: ...ense beverage press a cup or glass against the lever or push the button on the valve cover Replenishing Concentrate Supply Bag In Box System 1 Disconnect the concentrate tube from the empty bag in box...

Страница 11: ...dish washer detergent by using 70o F 21o C to 100o F 38o C potable water and 0 5 oz 15 ml of liquid dishwasher detergent to one gallon of potable water Stir detergent solution to thoroughly mix the s...

Страница 12: ...ntrate system 6 Allow sanitizing solution to remain in the concentrate systems for not less than 10 or no more than 15 minutes STEP 4 Water Flush Concentrate Systems WARNING Flush sanitizing solution...

Страница 13: ...Non Carbonated Impulse Installation Operations Manual 2003 IMI Cornelius Inc 9 Publication Number 859000159INS REFERENCE MATERIAL WIRING DIAGRAM...

Страница 14: ...DIAGRAMS Internal Carbonator External Carbonator COOLING COILS DISPENSER CARBONA TED W A TER MANIFOLD PLAIN W A TER LINELEGEND CO2 PLAINW A TER SYRUP 1 2 3 4 5 6 SYRUPSUPPL Y SYRUPT ANKSOR BAG IN BO...

Страница 15: ...Non Carbonated Impulse Installation Operations Manual 2003 IMI Cornelius Inc 11 Publication Number 859000159INS...

Страница 16: ...icted Sanitize syrup system as instructed Improper Baume of concen trate Replace concentrate supply Dirty or inoperative concen trate flow regulator Disassemble and clean dis pensing valve concentrate...

Страница 17: ...WILL NOT STOP AFTER SUFFICIENT ICE BANK IS FORMED Inoperative thermistor Replace thermistor Damaged ice bank control wire Repair ice bank control Inoperative control board Replace control board COMPR...

Страница 18: ...breaker note Fuse or circuit breaker are not part of unit Agitator motor propeller obstructed Remove obstruction Low voltage at compressor ter minals Voltage must be at least 103 volts at the compres...

Страница 19: ...blank...

Страница 20: ...IMI Cornelius Inc One Cornelius Place Anoka MN 55303 1592 U S A...

Отзывы: