Non-Carbonated Impulse Installation & Operations Manual

© 2003, IMI Cornelius Inc.

- 3 -

Publication Number: 859000159INS

I

NSTALLATION

 P

ROCEDURE

Counter-top Installation

NOTE:  Optional 4-inch legs (p/n 3184) will elevate the unit 4 inches above counter (order 4 legs). 

1.

Place the unit on a level counter capable of supporting at least 400 pounds. 

2.

Remove drip tray and front access panel.

3.

Turn power switch off then remove screw located next to the power switch and the screw at top of 

front panel. Next, remove front panel, disconnect wires to valve key lock switch, and peal back 
magnetic decals from the top. Lift off top center section.

4.

Pull water, concentrate, and CO

2

 lines through counter or wall. To comply with NSF International 

requirements the unit must be sealed to the counter top and all access holes in the unit base must 
be sealed, or the unit can be installed using the optional 4-inch legs (P/N 3184). Caulk/seal the unit 
to the counter using Dow Corning RTV 731 or equivalent approved sealant. 

5.

Pull plastic “wire tie” to remove hitch pin from condenser fan motor assembly (this pin is only 

needed during shipping).

6.

Fill the water bath with clean water until it comes out the overflow tube. Make sure the overflow tube 

is not blocked or plugged. Use low-mineral tap water, not distilled or deionized water.

NOTE:   Water bath must be filled with water before the unit will run.

GLOBAL ICE BANK CONTROL (GIBO) THEORY OF OPERATION

Wire Tie

Hitch Pin

Fill water

bath through

hole in top

Once electrical power is supplied to the 
Unit, the agitator motor will start. There will 
be a three-minute time delay before the 
refrigeration compressor and the con-
denser fan motor will start. This three-
minute time delay will take place each time 
electrical power to the Unit is interrupted.

The Unit will continue to operate until ice 
covers all three stainless-steel pins on the 
ice bank control probe. The ice bank control 
module senses this by measuring the differ-
ence in electrical resistance between the 
water and the ice. When the ice on the 

evaporator coil becomes thick enough, it 
covers the three stainless-steel pins on the 
ice bank control probe. The control module 
senses there is enough ice and turns the 
refrigeration compressor and the con-
denser fan motor off.

The Unit remains turned off until the ice 
bank control three stainless-steel pins are 
free of ice. Once this happens, the ice bank 
control module starts the refrigeration com-
pressor and the condenser fan motor.

Содержание Impulse Non-Carbonated Post-Mi

Страница 1: ...IMPULSE Non Carbonated Post Mix Beverage Dispenser Installation Operation Manual Release Date December 16 2003 Publication Number 859000159INS Revision Date NA Revision A www cornelius com...

Страница 2: ...quipment Appropriate safety precautions should be followed and all local safety and construction requirements should be met To inquire about current revisions of this and other documentation or for as...

Страница 3: ...mmary 2 Electrical Requirements 2 Installation Procedure 2 Counter top Installation 2 Connect Concentrate and Water Lines 4 Adjust Water To Concentrate Ratio 4 Adjusting Flow Rates 5 OPERATIONS 6 Oper...

Страница 4: ...Impulse Installation and Operation Manual Publication Number 859000159INS ii 2003 IMI Cornelius Inc...

Страница 5: ...ion must be observed in the pre vention of CO2 gas leaks in the entire CO2 and soft drink system If a CO2 gas leak is suspected particularly in a small area immediately ventilate the contaminated area...

Страница 6: ...nt or rear counter must be level and able to support 400 lbs Environment indoor installation only Temperature 40 to 110 F ambient temperature Clearance 18 inches above 6 inches on sides and rear CO2 7...

Страница 7: ...th with clean water until it comes out the overflow tube Make sure the overflow tube is not blocked or plugged Use low mineral tap water not distilled or deionized water NOTE Water bath must be filled...

Страница 8: ...equired If water supply pressure to the unit is more than 50 psi a water pressure regulator must be installed in the supply line NOTE A water shutoff valve and water filter in the water supply line ar...

Страница 9: ...he flow rate of the water is 5 times that of the concentrate If the desired finished drink flow rate is 3 0 ounces per second then the water flow rate is 2 5 oz sec and the concentrate flow rate is 0...

Страница 10: ...ense beverage press a cup or glass against the lever or push the button on the valve cover Replenishing Concentrate Supply Bag In Box System 1 Disconnect the concentrate tube from the empty bag in box...

Страница 11: ...dish washer detergent by using 70o F 21o C to 100o F 38o C potable water and 0 5 oz 15 ml of liquid dishwasher detergent to one gallon of potable water Stir detergent solution to thoroughly mix the s...

Страница 12: ...ntrate system 6 Allow sanitizing solution to remain in the concentrate systems for not less than 10 or no more than 15 minutes STEP 4 Water Flush Concentrate Systems WARNING Flush sanitizing solution...

Страница 13: ...Non Carbonated Impulse Installation Operations Manual 2003 IMI Cornelius Inc 9 Publication Number 859000159INS REFERENCE MATERIAL WIRING DIAGRAM...

Страница 14: ...DIAGRAMS Internal Carbonator External Carbonator COOLING COILS DISPENSER CARBONA TED W A TER MANIFOLD PLAIN W A TER LINELEGEND CO2 PLAINW A TER SYRUP 1 2 3 4 5 6 SYRUPSUPPL Y SYRUPT ANKSOR BAG IN BO...

Страница 15: ...Non Carbonated Impulse Installation Operations Manual 2003 IMI Cornelius Inc 11 Publication Number 859000159INS...

Страница 16: ...icted Sanitize syrup system as instructed Improper Baume of concen trate Replace concentrate supply Dirty or inoperative concen trate flow regulator Disassemble and clean dis pensing valve concentrate...

Страница 17: ...WILL NOT STOP AFTER SUFFICIENT ICE BANK IS FORMED Inoperative thermistor Replace thermistor Damaged ice bank control wire Repair ice bank control Inoperative control board Replace control board COMPR...

Страница 18: ...breaker note Fuse or circuit breaker are not part of unit Agitator motor propeller obstructed Remove obstruction Low voltage at compressor ter minals Voltage must be at least 103 volts at the compres...

Страница 19: ...blank...

Страница 20: ...IMI Cornelius Inc One Cornelius Place Anoka MN 55303 1592 U S A...

Отзывы: