Daily Cleaning

1.

Remove nozzle assembly and rinse with warm (not hot) water. If possible, soak nozzle assembly 

over night in carbonated water then rinse with warm water.

2.

Wash external surfaces with mild soap solution, rinse with clean water, and wipe dry. Remove the 

drip tray, wash with mild soap solution, rinse and dry.

NOTE:  Do not use abrasive or harsh cleaners on the unit.

Daily Checks

1.

Check CO

2

 supply.

2.

Check concentrate supply.

Sanitizing Concentrate Systems

The concentrate systems should be sanitized at least every 120-days and before or after storage. Use a 
non-scented liquid household bleach containing a 5.25% sodium hypochlorite concentration per the fol-
lowing procedure:

IMPORTANT:  Only qualified Service Personnel should perform sanitizing procedure on the post-
mix

1.

Rinse bag-in-box connectors (concentrate bag-in-box systems) in warm potable water.

STEP 1. Wash Concentrate Systems

1.

Using a five-gallon container (bag-in-box system), prepare a full tank or container of liquid dish-

washer detergent by using 70

o

F (21

o

C) to 100

o

F (38

o

C) potable water and 0.5 oz. (15 ml) of liquid 

dishwasher detergent to one gallon of potable water. Stir detergent solution to thoroughly mix the 
solution.

2.

Bag-in Box Concentrate Systems.

A.  Install bag valves, cut from empty bag-in-box concentrate containers, on ends of concentrate 

containers concentrate outlet tubes connectors.

B.  Place all concentrate outlet tubes, with bag valves on their ends, in container containing deter-

gent solution.

3.

Flush the concentrate system and dispensing valve as follows:

A.  Place waste container under applicable dispensing valve.

B.  Activate the dispensing valve for one minute to purge all concentrate and flush out the concen-

trate system.

4.

Repeat the process for each concentrate circuits. 

5.

Remove detergent solution source from the concentrate system.

STEP 2. Flush Concentrate Systems

Fill five-gallon container with potable water, then place all bag-in-box concentrate containers concentrate 
outlet tubes in container containing potable water.

1.

Flush detergent solution out of the concentrate system and dispensing valve as follows:

A.  Place waste container under applicable dispensing valve.

B.  Activate the dispensing valve for one minute to purge all detergent solution and flush out the con-

centrate system.

Diffuser

Nozzle

Содержание Impulse Non-Carbonated Post-Mi

Страница 1: ...IMPULSE Non Carbonated Post Mix Beverage Dispenser Installation Operation Manual Release Date December 16 2003 Publication Number 859000159INS Revision Date NA Revision A www cornelius com...

Страница 2: ...quipment Appropriate safety precautions should be followed and all local safety and construction requirements should be met To inquire about current revisions of this and other documentation or for as...

Страница 3: ...mmary 2 Electrical Requirements 2 Installation Procedure 2 Counter top Installation 2 Connect Concentrate and Water Lines 4 Adjust Water To Concentrate Ratio 4 Adjusting Flow Rates 5 OPERATIONS 6 Oper...

Страница 4: ...Impulse Installation and Operation Manual Publication Number 859000159INS ii 2003 IMI Cornelius Inc...

Страница 5: ...ion must be observed in the pre vention of CO2 gas leaks in the entire CO2 and soft drink system If a CO2 gas leak is suspected particularly in a small area immediately ventilate the contaminated area...

Страница 6: ...nt or rear counter must be level and able to support 400 lbs Environment indoor installation only Temperature 40 to 110 F ambient temperature Clearance 18 inches above 6 inches on sides and rear CO2 7...

Страница 7: ...th with clean water until it comes out the overflow tube Make sure the overflow tube is not blocked or plugged Use low mineral tap water not distilled or deionized water NOTE Water bath must be filled...

Страница 8: ...equired If water supply pressure to the unit is more than 50 psi a water pressure regulator must be installed in the supply line NOTE A water shutoff valve and water filter in the water supply line ar...

Страница 9: ...he flow rate of the water is 5 times that of the concentrate If the desired finished drink flow rate is 3 0 ounces per second then the water flow rate is 2 5 oz sec and the concentrate flow rate is 0...

Страница 10: ...ense beverage press a cup or glass against the lever or push the button on the valve cover Replenishing Concentrate Supply Bag In Box System 1 Disconnect the concentrate tube from the empty bag in box...

Страница 11: ...dish washer detergent by using 70o F 21o C to 100o F 38o C potable water and 0 5 oz 15 ml of liquid dishwasher detergent to one gallon of potable water Stir detergent solution to thoroughly mix the s...

Страница 12: ...ntrate system 6 Allow sanitizing solution to remain in the concentrate systems for not less than 10 or no more than 15 minutes STEP 4 Water Flush Concentrate Systems WARNING Flush sanitizing solution...

Страница 13: ...Non Carbonated Impulse Installation Operations Manual 2003 IMI Cornelius Inc 9 Publication Number 859000159INS REFERENCE MATERIAL WIRING DIAGRAM...

Страница 14: ...DIAGRAMS Internal Carbonator External Carbonator COOLING COILS DISPENSER CARBONA TED W A TER MANIFOLD PLAIN W A TER LINELEGEND CO2 PLAINW A TER SYRUP 1 2 3 4 5 6 SYRUPSUPPL Y SYRUPT ANKSOR BAG IN BO...

Страница 15: ...Non Carbonated Impulse Installation Operations Manual 2003 IMI Cornelius Inc 11 Publication Number 859000159INS...

Страница 16: ...icted Sanitize syrup system as instructed Improper Baume of concen trate Replace concentrate supply Dirty or inoperative concen trate flow regulator Disassemble and clean dis pensing valve concentrate...

Страница 17: ...WILL NOT STOP AFTER SUFFICIENT ICE BANK IS FORMED Inoperative thermistor Replace thermistor Damaged ice bank control wire Repair ice bank control Inoperative control board Replace control board COMPR...

Страница 18: ...breaker note Fuse or circuit breaker are not part of unit Agitator motor propeller obstructed Remove obstruction Low voltage at compressor ter minals Voltage must be at least 103 volts at the compres...

Страница 19: ...blank...

Страница 20: ...IMI Cornelius Inc One Cornelius Place Anoka MN 55303 1592 U S A...

Отзывы: