5

630460070

INSTALLATION

This section covers unpacking and inspection, selecting location, installing Unit, preparing for operation, and
operation. Installation and start-up of the equipment should be performed by the distributor or the dealer’s 
professional staff.

LOCATION OF EQUIPMENT

For maximum performance the location should be away from heat sources such as ovens, direct sunlight, hot
air discharge, etc.

To reduce cost of maintenance and loss of efficiency, avoid placing air-cooled equipment in areas where grease,
flour and other airborne contaminants are present. Allow a minimum of 6” (15.24 cm) clearance at the front for
proper air circulation. Restricted air circulation will affect the efficiency  and required maintenance of the prod-
uct.

IMPORTANT: Never operate your equipment in room temperature below 50

_

F (10 

_

C) OR ABOVE

100

_

F(38

_

C). Should the location of your product ever be exposed to freezing temperatures, it must be

shut down and winterized.

FIGURE 1. INSTALLATION

AIR COOLED

WATER COOLED

SHUT-OFF VALVE

WATER FILTER

BIN DRAIN TUBE

ELECTRICAL CORD

TO OUTLET

DUMP VALVE

DRAIN TUBE

FLOOR DRAIN

DUMP VALVE

DRAIN TUBE

FLOOR DRAIN

ELECTRICAL CORD

TO OUTLET

BIN DRAIN TUBE

CONDENSER

WATER OUT

CONDENSER

WATER IN

EVAPORATOR

WATER IN

PLUMBING CONNECTIONS

1. All plumbing lines and connections must conform to local and national plumbing codes.

2. Line shut-off valves must be located in supply water lines for cuber and condenser if product is water-

cooled. Water supply to water-cooled condenser must include a stand-pipe to prevent “water hammer”.

3. Should your local water supply quality require the installation of a water filter system, consult your local dis-

tributor or dealer for proper size required.

4. Water supply pressure must not be lower the 20 PSI (1.37 BAR), nor should it exceed 120 PSI (8.16

BAR).

IMPORTANT: water filters larger than 5 microns do not give proper protection. Water pressures above
80 PSI (5.44 BAR) will destroy the filter.

Содержание IACS224

Страница 1: ...ctive by test Water pipe connections and fixtures directly connected to a potable water supply shall be sized installed and maintained according to Federal State and Local Codes PRINTED IN U S A IMI C...

Страница 2: ...5 ELECTRICAL 7 INSTALLATION CHECK POINTS 7 START UP AND CHECK OUT 8 OWNER OPERATOR 9 CLEANING PROCEDURES 9 PREP CLEANING 9 CLEANING THE WATER SYSTEM AND EVAPORATOR 9 SANITIZING PROCEDURES 10 DUMP CYCL...

Страница 3: ...Do not let anyone operate the machine without instructions Keep your machine in proper working condition Unauthorized modifications to the machine may impair function and or safety and affect the mac...

Страница 4: ...2 630460070 THIS PAGE LEFT BLANK INTENTIONALLY...

Страница 5: ...cartons for visible damage Open and inspect as required before the driver leaves and have him or her note any damage on the receipts All damaged claims must be inspected within 15 days of delivery Not...

Страница 6: ...CULATION FAN MOTOR Water Cooled and Remote Systems only Volts 115 220 115 220 Phase 1 1 1 1 Hertz 60 50 60 50 Amps Running 1 4 1 4 36 17 Watts 35 35 6 5 WATER PUMP Volts 115 220 115 220 Phase 1 1 1 1...

Страница 7: ...ct ever be exposed to freezing temperatures it must be shut down and winterized FIGURE 1 INSTALLATION AIR COOLED WATER COOLED SHUT OFF VALVE WATER FILTER BIN DRAIN TUBE ELECTRICAL CORD TO OUTLET DUMP...

Страница 8: ...6 630460070 FIGURE 2 CUBER INSTALLATION...

Страница 9: ...ls is affected causing pressure variations These pressure variations can result in low or a failed ice harvest 1 Has bin and cuber been leveled and sanitized 2 Does electrical and plumbing meet code r...

Страница 10: ...evaporator cools to 25_F 3 9_ C Depress the manual harvest switch located on the circuit board The fan motor will stop and the water dump valve will open in 3 seconds the hot gas solenoid will open a...

Страница 11: ...e in the storage bin or dispenser must be removed WARNING When using any chemical rubber gloves and eye protection should be worn PREP CLEANING Use full strength ice machine cleaner on a coarse surfac...

Страница 12: ...ion common liquid laundry bleach to the water pan and allow the pump to circulate the solution for 5 minutes You may also use a commercial sanitizer such as Calgon Ice Machine Sanitizer following the...

Страница 13: ...itch the pump will stop and the float will return the water level back to its original setting and shut off the wa ter supply 3 You have the option of selecting dump cycle intervals of S every cycle S...

Страница 14: ...F Dump Every Third Harvest 3 OFF ON Dump Every Seventh Harvest S3 2 S3 2 S3 2 Condenser Sensor Harvest Voltage Set point pins 2 and 3 Factory setting 1 224 V GR GR GR GR Fan Dump Gear Gas Pump FIGURE...

Страница 15: ...vest cycle As the ice harvest bar swings closed the ice machine returns into the freezing cycle FULL BIN CONTROL A bin thermostat is provided to control the level of the ice in the storage bin When th...

Страница 16: ...er normal operating conditions Models IACS50 AC322 and WC322 are excluded from this warranty clause LIMITED LABOR WARRANTY PERIOD In addition to the parts warranty CORNELIUS will pay scheduled straigh...

Страница 17: ...15 630460070 THIS PAGE LEFT BLANK INTENTIONALLY...

Страница 18: ...One Cornelius Place Anoka Minnesota 55303 6234 Telephone 800 238 3600 Facsimile 763 422 3246 Corporate Headquarters IMI CORNELIUS INC...

Отзывы: