background image

Technical service manual 

GEO 10

17

In this case there are two lines with an index of “_-4=”
It is important not to repeat two lines with the same index so, in view of what has just been 
said, we recommend that you insert, in the file “Printer.ini”, the indices of the print quality 
which can presumably be used to print the aligner reports

NB: if more than one sheet is printed, with the subsequent sheets showing only a part of 
the text and not a cut part of the graphics, check first of all that the dimensions of the 
paper used correspond to the paper dimensions set in the printer.

Setting the customer LOGO for paper printouts

To customise the print on paper (adding the customer’s logo), it is necessary to enable it
in the aligner set-up and modify the following files:

imgprbarra3.bmp
imgprbarra4.bmp

These files are installed in the path:

c:\program files\alignment\graphics\image

.

The logo size must be 1100x354 pixel.

ENABLING EXTRA WHEEL ALIGNER 

FUNCTIONS

Additional wheel aligner functions are enabled by updating its main protection SIM 
CARD.
Upgrading is performed with the “Upgrade SIM CARD” obtained by ordering the relati-
ve accessory kit.
The “upgrade cards” obtained by ordering the relevant accessory kit carry specific 
identification symbols:

Animated
Adjustment
Procedure

Card which enables the aligner for use of animated adjustment help 
functions..

Audi
VW
Procedure

Card which enables the procedure for aligning cars made by the 
AUDI / VOLKSWAGEN automotive group.

Mercedes
Benz
Procedure

Card which enables the procedure for aligning MERCEDES cars.

To update the main SIM CARD, the card must first be inserted in the Hard Lock (Fig. 3) 

and and run the relative procedure using icons 

,

Содержание GEO 10

Страница 1: ...WHEEL ALIGNER GEO 10 03 2014 SERVICE MANUAL UK...

Страница 2: ......

Страница 3: ...CTIONS 17 HEADS 19 CALIBRATION 21 UTILITY PROGRAMS 24 SERVICE PROGRAM 25 RADIO 27 INSTALLING THE DATABANK UPGRADE 31 INSTALLING THE SOFTWARE UPGRADE 31 GENERAL ELECTRICAL WIRING DIAGRAM FIG 19 35 All...

Страница 4: ...e four measuring sensors are fitted with microcontroller boards for full control of the angle measuring sensors infrared CMOS goniometers and the electronic inclinometers for measuring the camber and...

Страница 5: ...elease installed will be displayed on the screen centre left Compare this release with that stated on the installation CD ROM supplied with the aligner If the CD ROM release is more recent than the re...

Страница 6: ...wer supply is on The yellow LED lights up to indicate that communication with the connected head has been established successfully HARD LOCK Fix the Hard Lock device B Fig 3 and the 2 charging cable r...

Страница 7: ...Default Menu Submenu Item Parameter Advanced Peripheral configuration Parallel port Disable Audio Disable On Board Lan Disable Video configuration DVMT Fixed IGD DVMT Memory 128Mb Primary video adapto...

Страница 8: ...nu Submenu Item Parameter Advanced Peripheral configuration Parallel port Disable Audio Disable On Board Lan Disable Video configuration IGD DVMT Memory 128Mb Primary video adaptor Int Graphics IGD Ch...

Страница 9: ...User name User Password user NOTE the wheel aligner must be set for access by means of the Administrator user name When the machine is switched on the release of the software installed will appear on...

Страница 10: ...10 Technical service manual GEO 10 Instructions for changing the language settings 1 Open the Control Panel 2 Open Date Time Language and Regional Options 3 Select Regional and Language Options...

Страница 11: ...Technical service manual GEO 10 11 2 1 4 Select the language required from the pull down menu and click on Customize 5 Select the Time menu...

Страница 12: ...12 Technical service manual GEO 10 6 Select the HH mm ss format and confirm by clicking on OK 7 Select Languages...

Страница 13: ...ervice manual GEO 10 13 8 Select the language required from the pull down menu see below for order in which languages appear Then select the Advanced menu and select the language required from the pul...

Страница 14: ...14 Technical service manual GEO 10 Confirm the selections by clicking on OK 9 Click YES in the next window 10 Click on OK restart the PC and continue with the usual testing operations...

Страница 15: ...ile Printer ini there could also be the names of other printer models with their respective settings d Identify the line corresponding to the one just printed generally the last line at the end of the...

Страница 16: ...replaced the number after with the chosen resolution value Note the setting of the file printer ini is made by repeating the entire procedure ex plained above starting from point a and following the p...

Страница 17: ...ify the following files imgprbarra3 bmp imgprbarra4 bmp These files are installed in the path c program files alignment graphics image The logo size must be 1100x354 pixel ENABLING EXTRA WHEEL ALIGNER...

Страница 18: ...ARD NB Insert the tip of a pen into the hole at the side of the Hard Lock to open the SIM holder Fig 7 The upgrade SIM CARD cannot be reused However keep it for use if it becomes ne cessary to reprogr...

Страница 19: ...s to the central unit the angles read by means of the goniometers and the inclinometers The measuring sensors are assigned to the wheels of the vehicle via switches 1 and 2 of the DIP_SWITCH PRG of th...

Страница 20: ...alibrated 6 beeps Full scale of inclinometer and both goniometers not calibrated 7 beeps Thermal characterization of inclinometer missing 8 beeps If goniometer calibration is missing head will beep 1...

Страница 21: ...test page until they are run down Note When fully charged new batteries will ensure 8 hours of continuous operation CALIBRATION Calibration program This window allows the user to check and or perform...

Страница 22: ...ace two high shims under feet 1 and 2 Wait for the data acquisition Place the low shim under foot 3 and then the medium shim under foot 2 Wait for the data acquisition Place the low shim under foot 3...

Страница 23: ...current screen Warning If some values are outside the permitted tolerance ranges the zero and full scale calibration procedure should be performed Before performing the zero and full scale setting pro...

Страница 24: ...halts and signals the out of range condition Heads Test Programme This window allows the user to check that the measuring sensors are working correctly when they are fitted to the wheels of a vehicle...

Страница 25: ...e wheel aligner program and go to the operating system using icon and digit the password end in lowercase letters Click twice on icon Alig_Service_USB exe The Service program will open When the progra...

Страница 26: ...ssion for the infrared LEDs of the goniometers EncP 0 Resets the turntable encoder Spegni Switches off the heads VerSw Shows the firmware release currently installed on the heads Software Head firmwar...

Страница 27: ...ctrical panel as displayed and press OK The upgrade will start Wait for completion of the procedure When the procedure has been completed successfully switch off the measuring he ads disconnect the ba...

Страница 28: ...ction controls the PC radio Hardlock and measuring sensor radio chan nel heads The lower function is used to program the PC radio Hardlock firmware Hardlock Radio channel read and write operations Rea...

Страница 29: ...ROGRAMMING button located in section Radio PC 2 Wait for the message confirming that data was written successfully 3 Press the OK button 4 Perform a reading operation of the configuration of the radio...

Страница 30: ...radio modules to ensure that the procedure was completed successfully Channel must be set to 40 Operation with other radio aligners If other aligners of the same type are installed in the same place...

Страница 31: ...owing the release date and time of generation of the service program ATTENTION None of the procedures described below require the re installation of the Operating System DATABANK UPGRADE The databank...

Страница 32: ...additional passwords not included in the previous release will be set at the default values NOTES Note 1 Messages which appear on the video during the databank update procedure Databank file upgrade s...

Страница 33: ...f the installation crashes during the file update the initial situation has to be restored before any further operations can be carried out Any second installation attempt performed without first rest...

Страница 34: ...From the logo video page access the page which summarises the characteristics of the SIM CARD Read the year of the databank which the SIM CARD is enabled to access Year field From the wheel aligner so...

Страница 35: ...ontaining the record of the jobs done WORK MDB this means losing the data If the damaged file is the main databank DBSTD MDB refer to the First installation or using an existing installation with a SI...

Страница 36: ...36 Technical service manual GEO 10 1 2...

Страница 37: ...Technical service manual GEO 10 37 4 3...

Страница 38: ...38 Technical service manual GEO 10 5 6...

Страница 39: ...Technical service manual GEO 10 39 7 8...

Страница 40: ...40 Technical service manual GEO 10 9 10...

Страница 41: ...Technical service manual GEO 10 41 19...

Страница 42: ...42 Technical service manual GEO 10 20 21...

Страница 43: ...Note 43...

Страница 44: ...CORMACH S r l via A Pignedoli 2 42015 CORREGGIO RE ITALY Tel 39 0522 631274 Fax 39 0522 631284 e mail cormach cormachsrl com www cormachsrl com...

Отзывы:

Похожие инструкции для GEO 10