55
9.
Control mode setup
Setup the control mode by following procedure
1.
Open the System setting window.
2.
Configure the Master IPS system and transmit.
* After transmitting, power must be cycled for this setting to take effect.
No. Name
Explanation
(1)
Master No(= ID)
The Master IPS ID which communicates with PC is displayed.
(2)
Connection Spindle
Configure the number of IPS (ID) connected with the Master IPS.
(3)
RS-485
Configure the Baud Rate of between Master and IPS
(Default 19200)
(4)
I/O Mode
Select the DeviceNet or the Parallel I/O.
(5)
Name
The Name of Master IPS can be input.
(as the need arises)
(6)
Mode
Select the control mode
Multi: Spindle control and data collection.
Data: Data collection only.
(1)
(2)
(3)
(4)
(1)
(2)
(3)
(4)
(5)
(6)