11
3. Specification
3.1. General
specification
3.2. Basic
specification
Items Contents
Outline
Refer to outline diagram on the Appendix
(Section 3 (3) Master-IPS )
Temperature
0-45°C
Humidity
85% or less (No condensation)
Altitude
Altitude 1000m or lower
Installing location
Harmful places with corrosive gas, cutting oil, metalpowder,
oil etc
are not allowed.
Power for drive
24V DC
Power consumption
8W (Except option)
Grounding
Third-class earth work (Preferably 30
Ω
or less)
Cooling procedures
Natural air cooling
Installing procedures Installing on back panel
Type
M-IPS-NR M-IPS-NR
-DEV
M-IPS-NR
-PRF
M-IPS-NR
-CCL
M-IPS-NR
-INT
Open network
No DeviceNet
Profibus
(
under
development
)
CC-LINK
(
under
development
)
Interbus
(
under
development
)
EtherNet
UDP/IP protocol 10M/100Mbps
RS-485 Communication
For communication with IPS (Use either port)
19.2K/38.4K/76.8Kbps baud rate can be selected.
RS-232C Communication
For optional RS-232C devices×2
9.6K/19.2K/38.4Kbps baud rate can be selected. (Dedicated protocol)
Parallel Input
(
For only M-IPS-NR *1
)
16points
Capacity 24V, 4.8mA, Filter time constant 50ms
Parallel Output
(
For only M-IPS-NR *1
)
16points
Capacity 24V, 50mA, Filter time constant 50ms
Status indicator (LED)
1 color LED×2 (For judgment)
3 colors LED×2 (For status)
Number of IPS connection
32 spindles maximum
Number of sequence
(
Multi
)
Number of data table
(
Data
)
31 points
Alarm history
Latest 30 alarms