CL33600 Series Cylindrical Lock
15
Copyright © 2009 Corbin Russwin, Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the
express written permission of Corbin Russwin, Inc. is prohibited.
Typlcal CL33600 x M812 Series Lock Application Diagram (12/24VDC Lock)
12/24VDC SYSTEM
Reader Draw = 125mA
12VDC Solenoid Draw = 250mA
12VDC Total Current Draw = 375mA
24VDC Solenoid Draw = 150mA
24VDC Total Current Draw = 275mA
DIAGRAM #3 – MODE 3: LED WIRE TIED TO EAC PANEL = EAC PANEL CONFIGURABLE
6) Wiring Diagrams (Continued)
QC12
Electric Hinge
Power Supply
(By Others)
Access 600 Reader Requires
12 or 24 VDC Power
Electrical Access
Control Panel
(By Others)
Use (NC) for Fail
Safe Operation
Lock Relay
(NO) Fail Secure
Operation
DPS
DPS
DATA 1
DATA 0
RX (NO)
RX (COM)
LED
READER NEG - Black, 1
READER POS - Red, 2
DATA 1 - White, 3
DATA 0 - Green, 4
RX (NO) - Orange, 5
RX (COM) - Blue, 6
*EARTH GROUND - Brown, 7
LED - Yellow, 8
LOCK NEG - Violet, 9
LOCK POS - Gray, 10
DPS (NC) - Pink, 11
DPS (COM) - Tan, 12
CL33600
Series Lock
Door
Position
Switch
12/24 VDC
H N G
- +
120 VAC
Input
Black (Hot)
White (Neutral)
Gr
een (Gnd)
12 Conductor
ElectroLynx Harness
White (C)
Gr
een (NC)
*IMPORTANT: Pin 7 must be tied to earth ground in the access control panel.
Failure to follow proper ESD safe grounding procedures could lead to equipment failure.
Patent Pending