background image

12

CL33600 Series Cylindrical Lock

Copyright © 2009 Corbin Russwin, Inc., an ASSA ABLOY Group company. 

All rights reserved. Reproduction in whole or in part without the 

express written permission of Corbin Russwin, Inc. is prohibited.

Reader LED Configuration
The Harmony Series reader can be configured for (3) modes of LED operation. 
The Access 600 series reader can be configured for (3) modes of LED operation.  
Programming cards are supported to configure the behavior for LED color activity.
Call 1-800-WIRE for details. 
Mode 1:
• Red LED ‘ON’ when powered.
• Presenting a 13.56MHz proximity card will cause LED to ‘FLICKER’ green  
   and return to red state.
• Reference Diagram #1 or #4 as a function of power requirement  
   (12VDC or 24VDC).
   Note: LED wire is unconnected.
Mode 2:
• Green LED “ON” when powered.
• (No Flicker) after presenting valid 13.56MHz proximity card.
• Reference Diagram #2 or #5 as a function of power requirement (12VDC or 24VDC).
   Note: LED wire must be connected to circuit GROUND of the system’s  
   power supply. 

PIN8 (Yellow – LED)

PIN 6 (Blue – RX COM)

PIN 4 (Green – Data 0)

PIN 2 (Red – Reader POS)

PIN 1 (Black – Reader NEG)

PIN 3 (White – Data 1)

PIN 5 (Orange – RX NO)

PIN 7 (Brown - EGND)

PIN 4 (Tan – DPS)

PIN 2 (Gray – Lock POS)

PIN 1 (Violet – Lock NEG)

PIN 3 (Pink – DPS)

Mode 3:
• EAC Panel controls LED operation.
• Reference Diagram #3 or #6 as a function of power requirement (12VDC or 24VDC).
   Note: Control of LED is a function of the EAC panel equipment (ie. relay) to toggle between green and red.
   Note: When LED wire is tied directly into EAC panel relay, no AC signals should be applied on wire or door reader  
   performance will be interfered (refer to Diagram #3 or #6).

6) Wiring Diagrams

Product

8 PIN CONNECTION

4 PIN CONNECTOR

1-Black

2-Red

3-White

4-Green

5-Orange

6-Blue

7-Brown

8-Yellow

9-Violet

10-Gray

11-Pink

12-Tan

ACCESS CONTROL DEVICES: CL33600 TCRNE1 Series M12 - iCLASS ( ElectroLynx wire Color / Function assignments

12 or 24VDC 

Reader Power

WIE-

GAND

WIE-

GAND

RX

RX

EGND

LED

12 OR 24 VDC

(LOCK RELAY

NOT 

USED

NOT 

USED

Corbin Russwin

CL33600 M12

NEG

POS

DATA_1

DATA_0

NO

COM

EGND

REF.
DIA-

GRAMS

NEG

POS

N/A

N/A

Содержание CL33600

Страница 1: ...the lock and void the factory warranty Important The accuracy of the door preparation is critical for proper functioning and security of this lock Misalignment can cause premature wear and a lessening...

Страница 2: ...television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocat...

Страница 3: ...ntrol EAC panels The reader requires 12 or 24VDC for power and is compatible with HID iCLASS 13 56 technology The Access 600 technology is designed around Corbin Russwin s Grade 1 hardware The cylindr...

Страница 4: ...ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Corbin Russwin Inc is prohibited Tools Required Phillips Screw Driver Standard size F...

Страница 5: ...ges Left Open Inward LH Left Hand Reverse Bevel Hinges Left Open Outward LHRB Right Hand Hinges Right Open Inward RH Right Hand Reverse Bevel Hinges Right Open Outward RHRB 1 Verify Hand and Bevel of...

Страница 6: ...whole or in part without the express written permission of Corbin Russwin Inc is prohibited 5 Installation Instructions Continued 3 Install Latch Bolt with beveled bolt facing the strike using two 8...

Страница 7: ...rough 2 1 8 diameter hole from outside of door Be sure latch engages lock body as shown Fig 6b Important Door must remain open during installation Use door stop 6 Install Inside Spring Cassette a Feed...

Страница 8: ...win Inc an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Corbin Russwin Inc is prohibited 5 Installation Instructions Continue...

Страница 9: ...Wire a Insert reader assembly and route wires through door Fig 9a b Install two 8 32 x 1 3 4 flat head screws Fig 9b c Connect pin 5 green yellow ground wire ring terminal to top right screw Fig 9c Fi...

Страница 10: ...go on only one way Do not offset connector and be sure they are completely seated 5 Installation Instructions Continued 11 Connector Attachment Interior PCB Assembly Fig 11 J1 J2 To ElectroLynx Harnes...

Страница 11: ...15 a Drill 1 hole in door for magnet b Drill 1 hole in frame for switch c Wire to ElectroLynx frame harness as shown in wiring diagrams on following pages 15 Install Door Position Switch Supplied with...

Страница 12: ...must be connected to circuit GROUND of the system s power supply PIN8 Yellow LED PIN 6 Blue RX COM PIN 4 Green Data 0 PIN 2 Red Reader POS PIN 1 Black Reader NEG PIN 3 White Data 1 PIN 5 Orange RX NO...

Страница 13: ...0 Green 4 RX NO Orange 5 RX COM Blue 6 EARTH GROUND Brown 7 LED Yellow 8 LOCK NEG Violet 9 LOCK POS Gray 10 DPS NC Pink 11 DPS COM Tan 12 Not Used CL33600 Series Lock Door Status Switch 12 24 VDC H N...

Страница 14: ...TA 1 DATA 0 RX NO RX COM READER NEG Black 1 READER POS Red 2 DATA 1 White 3 DATA 0 Green 4 RX NO Orange 5 RX COM Blue 6 EARTH GROUND Brown 7 LED Yellow 8 LOCK NEG Violet 9 LOCK POS Gray 10 DPS NC Pink...

Страница 15: ...nge Power Supply By Others Access 600 Reader Requires 12 or 24 VDC Power Electrical Access Control Panel By Others Use NC for Fail Safe Operation Lock Relay NO Fail Secure Operation DPS DPS DATA 1 DAT...

Страница 16: ...configuration See reader LED Configuration c Present proximity credential and verify LED and sounder activity d Verify valid card read at EAC Panel e Verify system operation functions i e when prox c...

Отзывы: