4

M800 Programming

To Program Door Name into Keypad

99# Master Code*  

Yellow LED blinks

43# Door Name (up to 5 digits)#  

Yellow LED blinks

0#  

Yellow LED blinks quickly

*    

Yellow LED blinks slowly

*    

Yellow LED goes out 

To Interrogate Transaction Log

To output the last 1000 transactions:
99# Supervisor or Master Code* 

Yellow LED blinks

70# 0# 0#  

Yellow LED blinks

*    

Yellow LED blinks quickly

*    

Yellow LED goes out

When printing finishes, the green LED will turn off and the yellow LED will blink slowly.
*    

Yellow LED goes out

Sequence Number

Four digit – Rolling last 1000 transactions, 9999 is highest number
Latest transaction – Highest #, First to print
Oldest transaction – Lowest #, Last to print

Hold an infrared printer up to the infrared LED. (Figure 
3) An HP82240B Infrared Printer can be used to
download information from the keypad to a printout.

Note: The highest Seq. # is the programming 
request to output the entries. The balance of 
Sequence numbers are the actual entries. (Figure 4)

Infrared Printer

To LED location

793F109

Door    Name    5666

Seq

User

Trans

0005      001

0004      003

0003      003

Varies

0002      020

0001      003

Door Name

Transaction Number

User Number

Transaction Type

Figure 3 

Figure 4 

Содержание Access 800

Страница 1: ...inrusswin assaabloy com Copyright 2018 2019 Corbin Russwin Inc an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Corbin Russwin...

Страница 2: ...al by this user type will override any locked condition and will unlock the door including User Lockout and Panic Lockdown states Presentation of this user type also allows entry on a Access 800 morti...

Страница 3: ...l times until the yellow LED goes out If no keystroke is made in a 30 second time frame the programming up to that point will default and you will have to start over Lock Model _______________________...

Страница 4: ...r the Emergency Code 99 Master Code Yellow LED blinks 50 02 Yellow LED blinks Emergency 1 6 digits Yellow LED blinks quickly Emergency 1 6 digits Yellow LED blinks slowly Yellow LED goes out Emergency...

Страница 5: ...blinks 56 0 Enable User Location 04 100 or 1 Disable User Location 04 100 Yellow LED blinks Yellow LED blinks quickly Yellow LED blinks slowly Yellow LED goes out To Delete A User 99 Master Code Yell...

Страница 6: ...or or Master Code Yellow LED blinks 70 0 0 Yellow LED blinks Yellow LED blinks quickly Yellow LED goes out When printing finishes the green LED will turn off and the yellow LED will blink slowly Yello...

Страница 7: ...owly Yellow LED goes out To Clear the Entire Memory and restore Factory default settings 99 Master Code Yellow LED blinks 46 00000 00000 Yellow LED blinks Yellow LED blinks quickly Yellow LED blinks r...

Страница 8: ...2 Yellow LED blinks Supervisory 1 6 digits Yellow LED blinks quickly Supervisory 1 6 digits Yellow LED blinks slowly Yellow LED goes out Enter A User Code 99 Master Code or Supervisor Code Yellow LED...

Страница 9: ...a Lock Out User Code 99 Master Code or Supervisor Code Yellow LED blinks 50 3 User Location 03 2000 Yellow LED blinks User Code Yellow LED blinks quickly User Code Yellow LED blinks slowly Yellow LED...

Страница 10: ...enabled and this procedure does not have to be completed With the RF FOB function enabled the battery life of the unit will be reduced Press the white reset button located in the battery compartment...

Страница 11: ...owly Yellow LED goes out User Type Table Note 1 There is a time delay period between initially depressing the RF FOB button and the actuation of the lock In some cases the RF FOB will have to be depre...

Страница 12: ...Yellow LED blinks Yellow LED blinks quickly Yellow LED blinks slowly Yellow LED goes out 24Hr Format 1PM 13 00 2PM 14 00 10PM 22 00 Midnight 00 00 1 15PM 13 15 Daylight Savings Time 99 Master Code Yel...

Страница 13: ...ED blinks 50 0 User Number 03 2000 Yellow LED blinks Yellow LED blinks quickly Yellow LED blinks slowly Yellow LED goes out To Clear the Entire Memory 99 Master Code Yellow LED blinks 46 00000 00000 Y...

Страница 14: ...er Code 2 to 6 digits which correlates with the User Location 99 Master or Supervisor Code 50 Type User Location a User Code a User Code a Type User Location b User Code b User Code b T ULc UCc UCc T...

Страница 15: ...t up your system and Hotsync door information to PDA 2 Remove Battery Cover from inside of lock 3 On PDA select Access HH then Imp Exp PDA Response Please enter your Do NOT click OK at this point comm...

Страница 16: ...019 Corbin Russwin Inc an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Corbin Russwin Inc is prohibited Patent pending and or...

Отзывы: