Coopra TWIN80C Скачать руководство пользователя страница 7

user instructions TWIN80C_EN 

 

 

7

 

Tips 

Depending on how much you value optimum comfort and the 
lowest possible energy consumption, the following tips can help 
you make optimum use of your unit: 
To help limit the energy consumption, it is recommended to set 
the room thermostat to a lower temperature a few hours before 
going to bed. 
Turn all radiator taps fully open in the rooms that you want to 
heat. 
Shut the radiator taps off in the rooms where you do not want 
any heating. 
 

Cleaning the unit 

Regularly clean the outside of the unit with a soft, damp cloth. It 
is not necessary to shut the gas tap off or switch the mains off 
for this. 
Never use aggressive or flammable cleaning agents. 
Take note that the pipes can be at a high temperature. 
 

Holidays 

With long-term absence, for example in the holidays, it is 
recommended to leave the unit continually switched on. The 
reason is that the unit makes a number of checks every 24 
hours. 
If frost can be excluded, set the room thermostat to a lower 
temperature. 
If frost cannot be excluded, set the room thermostat to a 
temperature of 12°C or higher.  
Although the unit has an internal frost protection, this does not 
protect the whole installation against freezing. 

 
Brrrr, the central heating is not working 

In the unlikely event that the central heating has let you down, 
we have some tips for things that you can check and remedly 
yourself before an installer. 
 
The central heating boiler is a fairly complicated item that is 
fitted with safety devices, which prevent a dangerous situation. 
There can be many reasons why the central heating is not 
working. 
 

Electricity and gas 

Is the connection of the green block in the green socket correct 
connected?  
Is the main switch on the unit in the right position?  
Or is the circuit to which the boiler is connected out of operation 
because the fuse has blown or the earth leakage switch has 
activated? 
 
Is there an (unusual) interruption in the gas supply? Check by 
seeing whether a gas cooker in the kitchen is working. If it is not 
working, call the gas company. The gas flow can also be 
blocked because the gas filter of the boiler is contaminated; this 
is a problem for the service man. 
The unit also lets the pump regularly run outside the heating 
season to prevent it from sticking. If the mains supply outside is 
interrupted several times during the heating season, the pump 
can stick. Solution: turn the shaft of the pump a few times by 
hand (screwdriver). 
 

Water and air 

If the water pressure in the installation falls below a minimum 
level, the burner will be off.  
Solution: Top up with water. 
It is possible to read the water pressure directly from the display.  
Reading: Press the + button in for a minimum of 5 seconds. 
From the menu back to normal operation: Press the - button in 
briefly (or automatically after about 5 minutes). 
During filling, the unit must be connected to the mains and be 
switched on. 

Fully open all radiator taps. 
Connect the water supply to the filling connection of the 
installation. 
Open the tap to fill the system with water. 
When the water pressure is sufficient (> 1.3 bar), close the filling 
tap again. 
If there is air in the installation, the boiler can switch on, but the 
radiators remain cold. 
Follow the instructions from the manufacturer/installer for the 
venting of possible other elements of the heating installation, 
such as floor heating. 
Fully open all radiator taps. 
Vent the radiators after the pump is switched off. 
Open the air bleed cocks of the radiators one at a time. Use an 
air bleed key for this. 
As soon as water comes out of the air bleed cock, shut the cock 
off again. 
If the central heating boiler is at the highest point of the 
installation, air can collect in the boiler. This can cause a 
malfunction in the boiler. Also vent the internal tap pot (only with 
a Combi-unit). 
 

Other causes 

There must be heat demand from the room thermostat or other 
control, otherwise the boiler will not switch on. Set the 
thermostat to demand heat and check whether the boiler 
switches on; this can take a minute or so.  
 
If there is little water circulation because too many radiator taps 
are closed, the boiler will not function or will function 
insufficiently. In this case, open more radiator taps or ask your 
installer to fit a bypass valve. 

 
 
 
 
 

Содержание TWIN80C

Страница 1: ...E000129017 user instructions TWIN80C_EN MV190805 User instructions TWIN80C Wall hung fan flue room sealed gas boiler 2006 E000129017...

Страница 2: ...G is automatically added to the combustion air The flammable gas air mixture thus obtained is fed to the burner s via a mixing chamber to be ignited at the surface of the burner s by a ceramic glow p...

Страница 3: ...g heat demand burner off C Central heating heat demand burner on P C Central heating heat demand low load water pressure A C Central heating heat demand low load chimney temperature c Central heating...

Страница 4: ...etting return mode excluded are the settings under Letter h note for entering press button 5 sec Factory setting Customised setting u 0 10V regulation 0 Regulation on temperature C 1 Regulation on boi...

Страница 5: ...the subsequent Letter in menu parameter the user must press the Set Reset button To change the Range setting in the parameter the user must press the or the button Parameter C The setting in the menu...

Страница 6: ...ating water is no longer heated The unit pumps will continue to run for a previously set time to distribute the heat evenly over the heating installation Comfort mode field adjustable Menu parameter o...

Страница 7: ...ng call the gas company The gas flow can also be blocked because the gas filter of the boiler is contaminated this is a problem for the service man The unit also lets the pump regularly run outside th...

Страница 8: ...ver of this document This document is valid for the unit in its standard version Therefore the manufacturer cannot be held liable for any damage arising from specifications that deviate from the stand...

Отзывы: