background image

Air Conditioners

Installation 

and owner`s 

Manual

Models

:

C&H D

C INVERTER

 E

-

SERIES

Duct Type

 Unit

Thank you for choosing our product.

For proper operation, please read and keep this manual carefully.

If you have lost the Owner’s Manual, please contact the local

agent or visit www

.cooperandhunter.com

 or sent email to 

info

@cooperandhunter

.com 

or 

electronic version. C

&H

 reserves the right to interpret this manual which will be subject 

to any change due to product improvement without further notice.

CH-I

D

0

30

R

K

E

CH-I

D

0

35

R

K

E

CH-I

D

0

50

R

K

E

CH-I

D

0

71

R

K

E

CH-I

D

0

85

R

K

E

CH-I

D

1

00

R

K

E

CH-I

D

1

25

R

K

E

CH-I

D

1

40

R

K

E

CH-I

D

1

60

R

K

E

Содержание CH-ID0100RKE

Страница 1: ...u have lost the Owner s Manual please contact the local agent or visit www cooperandhunter com or sent email to info cooperandhunter com or electronic version C H reserves the right to interpret this...

Страница 2: ...Safety Notice 11 2 The Tools and Instruments for Installation 12 3 The Installation of the Indoor Unit 12 3 1 The Initial Check 12 3 2 Installation 13 4 Refrigerant Pipe 15 4 1 The Pipe Material 15 4...

Страница 3: ...installed must have the reliable electrical grounding facility and protection Please do not connect the grounding of this product to various kinds of air feeding ducts drain piping lightning protecti...

Страница 4: ...ating of circuit breakers ELB is detailed in outdoor instruction manual The method of connection of the appliance to the electrical supply and interconnection of separate components is detailed in bel...

Страница 5: ...vapour being present while the work is being performed 6 3 General work area All maintenance staff and others working in the local area shall be instructed on the nature of work being carried out Wor...

Страница 6: ...ment being worked upon prior to any removal of sealed covers etc If it is absolutely necessary to have an electrical supply to equipment during servicing then a permanently operating form of leak dete...

Страница 7: ...rcuit with inert gas Evacuate Purge again with inert gas Open the circuit by cutting or brazing The refrigerant charge shall be recovered into the correct recovery cylinders The system shall be flushe...

Страница 8: ...cing or decommissioning it is recommended good practice that all refrigerants are removed safely When transferring refrigerant into cylinders ensure that only appropriate refrigerant recovery cylinder...

Страница 9: ...uthority which authoriaes their competence to handle refrigerants safely in accordance with an industry recognized assessment specification Servicing shall only be performed as recommended by the equi...

Страница 10: ...ll be further specified in remote controller s manual Please read it carefully before using this appliance and keep it for future reference Remote controller optional ON OFF MODE FAN SLEEP SUPER SMART...

Страница 11: ...essor must run for at least 5 minutes once operational In the 5 minutes compressor will not stop even the room temperature reaches the setting temperature point unless you use remote controller to tur...

Страница 12: ...ng with mode interfere occurs Following shows the mode interfere scene Cooling Dry Heating Fan Cooling normal Dry mode interfere Heating Fan Outdoor unit always run with the mode of first indoor unit...

Страница 13: ...irmly clamp the interconnecting wires so their terminals receive no external stresses Incomplete connections or clamping may cause terminal overheating or fire After connecting all the wires be sure t...

Страница 14: ...it mm unit mm During installation do not damage the insulation material on the surface of the indoor unit Number 1 2 3 4 5 6 7 Tool Standard screwdriver Vacuum pump Charge hose Pipe bender Adjustable...

Страница 15: ...nd noise in electrical appliances Noise may be generated depending on the conditions under which the electric wave is generated even if a one meter allowance is maintained Do not install the indoor un...

Страница 16: ...from loosening 1 During the installation please cover the unit with the plastic cloth to keep it clean 2 Make sure that the unit is installed level by using a level or a plastic tube filled with water...

Страница 17: ...rs 3 After finishing connecting the refrigerant pipes keep it warm with the insulation material Fig 4 4 Piping insulation procedure 030 071 085 100 125 160 DANGER The pipe go through the hole with the...

Страница 18: ...e causing water leakage Drain piping passing indoors Drain sockets Referring the figure below insulate the drain socket and drain hose using the included large sealing pad Drain piping connections Do...

Страница 19: ...trol box 17 WARNING Fig 6 1 6 Electrical Wiring When clamping the wiring use the included clamping material as shown in the Fig 6 1 to prevent external pressure being exerted on the wiring connections...

Страница 20: ...until display 17 and press ENTER button to entering system parameter adaption state symbol stop blinking Select desired parameter code 10 by pressing button and press ENTER button to confirm Select d...

Страница 21: ...n the table are selected at the maximus current of the unit according to the European Standard En60 335 1 Use the wires which are not lighter than the ordinary polychloroprene sheathed flexible cord c...

Страница 22: ...nt possible harm to the environment or human health from uncontrolled waste disposal recycle it responsibly to promote the sustainable reuse of material resources To return your used device please use...

Отзывы: