background image

8

Indoor unit

Note:

 

The figures

 

are

 

based on the external views of the standard model.

          

Consequently

the shape may differ for the air conditioner model you have selected.

Wire remote controller

Wireless remote controller

     
      You can control the air-conditioner with the wire remote controller or wireless remote controller.
      

It

 

is

 

used

 

for

 

controlling

 

power

 

ON

/

OFF

,

setting

 

the

 

running

 

mode

temperature

,

 fan

 

speed

 

and

 

other

 

functions

.

     

There are different types of remote controllers that can be used.

     

Operation instructions will be further specified in remote controller's manual.

     

Please

 

read

 

it

 

carefully

 

before

 

using

 

this

 

appliance

 

and

 

keep

 

it

 

for

 

future

 

reference

.

Remote controller(optional)

ON/OFF

MODE

FAN

SLEEP

SUPER

SMART

IFEEL

DIMMER

TIMER ON

TIMER OFF

CLOCK

ON

 OFF

ON

 OFF

SWING

SWING

ON

 OFF

MODE

SMART

QUIET

DIMMER

ECONOMY

FEEL

SUPER

FAN SPEED

CLOCK

TIMER ON

TIMER OFF

SLEEP

TEMP.

TEMP.

SET     TEMP
ROOM    TEMP

C

AUTO

  NO

  .

  TIMER  ON

  TIMER  OFF  SET  TIMER

A

确 定

FUNC

TIMER

CANCEL

SWING

FAN

ENTER

ON/OFF

MODE

SLEEP

1

1

1

2

3

4

7

7

2

2

3

5

6

4

4

5

3

5

6

7

6

1. Air inlet
2. Electric box
3. Refrigerant pipe (Liquid)
4. Refrigerant pipe (Gas)
5. Drain pipe (Connect with pump)
6. Drain pipe
7. Air outlet

0

30

~0

71

1

25

~1

60

0

85

~1

00

DC Inverter E

-

Series 

Duct Type

 Unit 

Содержание CH-ID0100RKE

Страница 1: ...u have lost the Owner s Manual please contact the local agent or visit www cooperandhunter com or sent email to info cooperandhunter com or electronic version C H reserves the right to interpret this...

Страница 2: ...Safety Notice 11 2 The Tools and Instruments for Installation 12 3 The Installation of the Indoor Unit 12 3 1 The Initial Check 12 3 2 Installation 13 4 Refrigerant Pipe 15 4 1 The Pipe Material 15 4...

Страница 3: ...installed must have the reliable electrical grounding facility and protection Please do not connect the grounding of this product to various kinds of air feeding ducts drain piping lightning protecti...

Страница 4: ...ating of circuit breakers ELB is detailed in outdoor instruction manual The method of connection of the appliance to the electrical supply and interconnection of separate components is detailed in bel...

Страница 5: ...vapour being present while the work is being performed 6 3 General work area All maintenance staff and others working in the local area shall be instructed on the nature of work being carried out Wor...

Страница 6: ...ment being worked upon prior to any removal of sealed covers etc If it is absolutely necessary to have an electrical supply to equipment during servicing then a permanently operating form of leak dete...

Страница 7: ...rcuit with inert gas Evacuate Purge again with inert gas Open the circuit by cutting or brazing The refrigerant charge shall be recovered into the correct recovery cylinders The system shall be flushe...

Страница 8: ...cing or decommissioning it is recommended good practice that all refrigerants are removed safely When transferring refrigerant into cylinders ensure that only appropriate refrigerant recovery cylinder...

Страница 9: ...uthority which authoriaes their competence to handle refrigerants safely in accordance with an industry recognized assessment specification Servicing shall only be performed as recommended by the equi...

Страница 10: ...ll be further specified in remote controller s manual Please read it carefully before using this appliance and keep it for future reference Remote controller optional ON OFF MODE FAN SLEEP SUPER SMART...

Страница 11: ...essor must run for at least 5 minutes once operational In the 5 minutes compressor will not stop even the room temperature reaches the setting temperature point unless you use remote controller to tur...

Страница 12: ...ng with mode interfere occurs Following shows the mode interfere scene Cooling Dry Heating Fan Cooling normal Dry mode interfere Heating Fan Outdoor unit always run with the mode of first indoor unit...

Страница 13: ...irmly clamp the interconnecting wires so their terminals receive no external stresses Incomplete connections or clamping may cause terminal overheating or fire After connecting all the wires be sure t...

Страница 14: ...it mm unit mm During installation do not damage the insulation material on the surface of the indoor unit Number 1 2 3 4 5 6 7 Tool Standard screwdriver Vacuum pump Charge hose Pipe bender Adjustable...

Страница 15: ...nd noise in electrical appliances Noise may be generated depending on the conditions under which the electric wave is generated even if a one meter allowance is maintained Do not install the indoor un...

Страница 16: ...from loosening 1 During the installation please cover the unit with the plastic cloth to keep it clean 2 Make sure that the unit is installed level by using a level or a plastic tube filled with water...

Страница 17: ...rs 3 After finishing connecting the refrigerant pipes keep it warm with the insulation material Fig 4 4 Piping insulation procedure 030 071 085 100 125 160 DANGER The pipe go through the hole with the...

Страница 18: ...e causing water leakage Drain piping passing indoors Drain sockets Referring the figure below insulate the drain socket and drain hose using the included large sealing pad Drain piping connections Do...

Страница 19: ...trol box 17 WARNING Fig 6 1 6 Electrical Wiring When clamping the wiring use the included clamping material as shown in the Fig 6 1 to prevent external pressure being exerted on the wiring connections...

Страница 20: ...until display 17 and press ENTER button to entering system parameter adaption state symbol stop blinking Select desired parameter code 10 by pressing button and press ENTER button to confirm Select d...

Страница 21: ...n the table are selected at the maximus current of the unit according to the European Standard En60 335 1 Use the wires which are not lighter than the ordinary polychloroprene sheathed flexible cord c...

Страница 22: ...nt possible harm to the environment or human health from uncontrolled waste disposal recycle it responsibly to promote the sustainable reuse of material resources To return your used device please use...

Отзывы: