Special remarks 

Troubleshooting

If the trouble persists even after checking the following, contact your dealer and inform them of the items. 

according to the original setting.

 If Trouble Still Remains ...

   1.

   (1) Unit Model Name
   (2) Content of Trouble
   2.

 

No Operation

   Check whether the SET TEMP is set at the correct temperature.  

     

CAUTION

 

      

Not Cooling or

 

Heating

 

properly

  3.

 

 

      

Check for obstruction of air flow in indoor and outdoor units. 

      

Check if too many heating sources are located in the room.

      

Check if the air filter is clogged with dust.

      

Check if the doors or windows are open.

      

Check if the temperature condition is not within the operation range.

  4. This is Not Abnormal
      

Odour from indoor unit

       Unpleasant odour diffuses from indoor unit after a long period of time. Clean the air filter and panels or 
       allow a good ventilation.
      Sound from Deforming Parts
       During system start or stop, a sound might be heard. However, this is due to thermal deformation of plastic 
       parts. It is not  abnormal.
      

Steam from Outdoor Heat Exchanger 

       During defrosting operation, ice on the outdoor heat exchanger melts resulting in steam.
      Dew on Air Panel
       When the cooling operation continues for a long period of time under high humidity conditions, dew may 
       form on the air panel, please set the appliance at high fan speed and adjust louvers to the max. angle.
      Refrigerant Flow Sound 
       While the system is being started or stopped, sound from the refrigerant flow may be heard.

 3 minutes protection after compressor stop

    

 To protect compressor, it will be continue to be off for at least 3 minutes once it has stopped. 

 5 minutes protection

    

 Compressor must run for at least 5 minutes once operational. In the 5 minutes, compressor will not stop even 

    

 the room temperature reaches the setting

 

temperature

 

point unless you use remote

 

controller to turn off the 

     unit (all indoor unit can be turned off by user). 

 Cooling operation

    

 The fan of the indoor unit will never stop running in cooling operation. It continues to operate even if the 

     compressor stops working.   

 Heating operation

     Heating

 

capacity

 

depends

 

on

 

external

 

factors

 

like

 

outdoor

 

unit

 

temperature

Heating

 

capacity

 

might

 

decrease

     

if outdoor

 

ambient

 

temperature

 

is

 

too

 

low

.

 Anti-freezing function during cooling

  

 When the temperature of the air from the indoor outlet is too low, the unit will run for some time under the fan

  

 mode, to avoid frost or ice forming on the indoor heat exchanger.

 Cold air prevention

     In several minutes after the heating mode is started, the fan of the indoor unit will not run until the heat 
     exchanger of the indoor unit reaches a certain temperature

 

to

 

prevent

 

cold

 

draft

.

 Defrosting

    

 When the outdoor temperature is too low, frost or ice may form on the outdoor heat exchanger, reducing 

     heating performance. When this happens, a defrosting system of the air conditioner will operate. At the same 
     time the fan in the indoor unit stops (or runs at a very low speed in some cases), to prevent cold draft. After
     defrosting

 

is

 

over

the

 

heating

 

operation

 

and

 

fan

 

speed

 

restart

.

 Blow out the survival heating air

 

   

When stopping the air conditioner in normal operation, the fan motor will run with low speed for a while to blow

     out the residual heating air.

 

 Auto

 

re-start

 

from of Power Break

    

 When the power supply is recovered after power

 

break, all presets are still effective and the air-conditioner will

     run according to the previous setting.  

DC Inverter E

-

Series 

Duct Type

 Unit 

Содержание CH-ID0100RKE

Страница 1: ...u have lost the Owner s Manual please contact the local agent or visit www cooperandhunter com or sent email to info cooperandhunter com or electronic version C H reserves the right to interpret this...

Страница 2: ...Safety Notice 11 2 The Tools and Instruments for Installation 12 3 The Installation of the Indoor Unit 12 3 1 The Initial Check 12 3 2 Installation 13 4 Refrigerant Pipe 15 4 1 The Pipe Material 15 4...

Страница 3: ...installed must have the reliable electrical grounding facility and protection Please do not connect the grounding of this product to various kinds of air feeding ducts drain piping lightning protecti...

Страница 4: ...ating of circuit breakers ELB is detailed in outdoor instruction manual The method of connection of the appliance to the electrical supply and interconnection of separate components is detailed in bel...

Страница 5: ...vapour being present while the work is being performed 6 3 General work area All maintenance staff and others working in the local area shall be instructed on the nature of work being carried out Wor...

Страница 6: ...ment being worked upon prior to any removal of sealed covers etc If it is absolutely necessary to have an electrical supply to equipment during servicing then a permanently operating form of leak dete...

Страница 7: ...rcuit with inert gas Evacuate Purge again with inert gas Open the circuit by cutting or brazing The refrigerant charge shall be recovered into the correct recovery cylinders The system shall be flushe...

Страница 8: ...cing or decommissioning it is recommended good practice that all refrigerants are removed safely When transferring refrigerant into cylinders ensure that only appropriate refrigerant recovery cylinder...

Страница 9: ...uthority which authoriaes their competence to handle refrigerants safely in accordance with an industry recognized assessment specification Servicing shall only be performed as recommended by the equi...

Страница 10: ...ll be further specified in remote controller s manual Please read it carefully before using this appliance and keep it for future reference Remote controller optional ON OFF MODE FAN SLEEP SUPER SMART...

Страница 11: ...essor must run for at least 5 minutes once operational In the 5 minutes compressor will not stop even the room temperature reaches the setting temperature point unless you use remote controller to tur...

Страница 12: ...ng with mode interfere occurs Following shows the mode interfere scene Cooling Dry Heating Fan Cooling normal Dry mode interfere Heating Fan Outdoor unit always run with the mode of first indoor unit...

Страница 13: ...irmly clamp the interconnecting wires so their terminals receive no external stresses Incomplete connections or clamping may cause terminal overheating or fire After connecting all the wires be sure t...

Страница 14: ...it mm unit mm During installation do not damage the insulation material on the surface of the indoor unit Number 1 2 3 4 5 6 7 Tool Standard screwdriver Vacuum pump Charge hose Pipe bender Adjustable...

Страница 15: ...nd noise in electrical appliances Noise may be generated depending on the conditions under which the electric wave is generated even if a one meter allowance is maintained Do not install the indoor un...

Страница 16: ...from loosening 1 During the installation please cover the unit with the plastic cloth to keep it clean 2 Make sure that the unit is installed level by using a level or a plastic tube filled with water...

Страница 17: ...rs 3 After finishing connecting the refrigerant pipes keep it warm with the insulation material Fig 4 4 Piping insulation procedure 030 071 085 100 125 160 DANGER The pipe go through the hole with the...

Страница 18: ...e causing water leakage Drain piping passing indoors Drain sockets Referring the figure below insulate the drain socket and drain hose using the included large sealing pad Drain piping connections Do...

Страница 19: ...trol box 17 WARNING Fig 6 1 6 Electrical Wiring When clamping the wiring use the included clamping material as shown in the Fig 6 1 to prevent external pressure being exerted on the wiring connections...

Страница 20: ...until display 17 and press ENTER button to entering system parameter adaption state symbol stop blinking Select desired parameter code 10 by pressing button and press ENTER button to confirm Select d...

Страница 21: ...n the table are selected at the maximus current of the unit according to the European Standard En60 335 1 Use the wires which are not lighter than the ordinary polychloroprene sheathed flexible cord c...

Страница 22: ...nt possible harm to the environment or human health from uncontrolled waste disposal recycle it responsibly to promote the sustainable reuse of material resources To return your used device please use...

Отзывы: