Shenzhen Coolmay Technology Co.,Ltd
CX-WIFI-2NET module user manual
www.coolmay.com
Page
85
, Total 93 pages
Step 2: Configure the virtual serial port software
①
Add virtual serial port
:
Note:
The virtual serial port is set to an unoccupied COM port on the computer;
Network protocol selects TCP Client;
Target IP/domain name setting 120.76.116.193 (Note: The target
IP/domain name is Shenzhen Coolmay Technology domain name, which
must be connected with Coolmay server);
Target port setting 25565;
Registration ID setting in Advanced 43589
(
Note: Each CX-WIFI-2NET
module has a unique pair of registration IDs. Please specify the
registration ID according to the factory parameters. The registration ID
number corresponding to each module will be indicated on the product
label. If you forget or not save, please ask Coolmay for help.
)
After the creation is successful, as shown in the figure below, and change
the sync baud rate option in the option to unchecked: