![ControlOMatic PoolWarden Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/controlomatic/poolwarden/poolwarden_installation-and-operation-manual_2658893006.webp)
PoolWarden Manual www.poolwardentraining.com 530-205-4520 6
Maximum Electrical Specifications
ITEM
DESCRIPTION
LIMIT
Input Voltage
Maximum input AC voltage
220 VAC, 50-60 Hz
Input Current
Maximum input current
10 A
Relay Voltage
Maximum relay voltage
220 VAC
Relay Current
Maximum Relay Current
2.5 A
Temperature
Minimum/Maximum Operating Temperature
30/110 °F
Standby Current
Maximum operating current
0.1 A Max
pH
Measurement of pH
4.22 to 9.98
ORP
Oxidation Reduction Potential
0 to 999 mV
Temperature
Water temperature measurement.
32 to 122
°F
ITEM
DESCRIPTION
PW-XFC
PoolWarden controller with flow cell and sensors
PW-X
FC-P
Add 2 pigtails per pool for easy connection of external feeders
PW-X
FC-P
E
Add 2 pigtails per pool and Ethernet communication
PW-X
FC-E
Add Ethernet communication
PW-XMTD
PoolWarden controller with flow cell and sensors pre mounted on white back panel
PW-XMTD
-P
Add 2 pigtails per pool for easy connection of external feeders
PW-XMTD
-P
E
Add 2 pigtails per pool and Ethernet communication
PW-XMTD
-E
Add Ethernet communication
TrueDPD
Adds free chlorine measurement using the DPD colorimetric method. This is available
as a single and dual sensor.
X
In the above model numbers, replace the x for S (Single pool) or D (Dual Pool)
Certifications
Models and Options
4010758
Conforms to
UL STD 1563
Certified to CSA STD
C22.2 No. 218.1
NSF/ANSI 50 -
Equipment for
Swimming Pools, Spas, Hot
Tubs and Other Recreational
Water Facilities
http://info.nsf.org/Certified/Pools/Listin
gs.asp?Company=C0214550&Standar
d=050&