![ControlOMatic PoolWarden Скачать руководство пользователя страница 32](http://html1.mh-extra.com/html/controlomatic/poolwarden/poolwarden_installation-and-operation-manual_2658893032.webp)
PoolWarden Manual www.poolwardentraining.com 530-205-4520 32
Set-points in the Relay Setup menu. The Time Profiles allow for using the
night time setpoint at different times of each day. Zero “0” and Twenty Four
“24” are the default settings for each day and mean the time settings are
disabled in this menu. Simply scroll down to the day and press the Seven “7”
key to change the first time or the Nine “9” key to change the second time.
The time is based on a 24-Hour Military Time.
❑
Example: This represents an example if the Auxiliary 1 Relay is set to
“Heater” control type and the main Aux1 Relay Set-point is set to “On if
Temp < 80” and the secondary Set-point is set to “Night Temp < 70”. On
Sunday in the Advanced Menu change the first number “0” to “6”
(6:00am) and the second number “24” to “18” (6:00pm). This means that
the main set-point of “On if Temp < 80” will be followed when the time is
between 6:00am or 6:00pm on Sunday. If the time is less than 6:00am or
more than 6:00pm on Sunday then the secondary set-point of “Night
Temp < 70” will be followed.
⧫
ORP Cya Calibration:
Allows for the ORP to be reduced during night time
hours to adjust for the natural ORP increase during the evening hours if
Advanced
Edit: 7=1
st
, 9=2
nd
Time Profile 1
Sunday :0<24
Monday :0<24
Tuesday :0<24
Wednesday:0<24
Thursday :0<24
Friday :0<24
Saturday :0<24
ORP Cya Calibration
Dawn Hour 0 AM
Dusk Hour 0 PM
ORP1 Night Cya -0
Reset All Advanced
Cyanuric Acid is being used in the Pool. Simply set the Dusk and Dawn hour (0 to 24 Hour Military Time)
to when the sun rises and sets. Then enter the ORP Millivolt Adjustment Number in “ORP# Night Cya -0”
that the pool normally experiences at night. What usually happens in this case is at night the ORP rises
and PoolWarden will not feed any more sanitizer until the sun comes up the next day, but during the night
the actual chlorine dropped so in the morning the chlorine level may be low. Lowering the ORP value at
night will allow for sanitizer to still be fed even in the presence of cyanuric acid. In order to set this value
observe the ORP reading at noon and midnight with the same sanitizer level, if the cyanuric acid had no
impact the ORP values would be the same. Subtract the midnight ORP reading from the noon ORP
reading and this is the value that can be entered, enter a number less to be conservative.
❑
Example: If the pool normally experiences a 125 Millivolt Increase between the hours of 7:00pm and
6:00am then enter “6” for the Dawn hour, 19 for the Dusk hour and 125 in “ORP Night Cya -125”, to
be conservative enter 75 instead of 125. PoolWarden will now adjust the ORP Reading by -125
Millivolts to normalize the reading during the night time hours.
⧫
Reset All Advanced:
Reset all the Advanced Menu settings back to the default settings which disables
this menu unit new settings are entered.