Unidrive M200/201 Control Quick Start Guide
45
Issue Number: 3
Digital I/O Read Word
reflects the state of digital inputs/outputs 1 to 5 and the relay.
Reference On
, which is controlled by the drive sequencer, indicates that the reference from the
reference system is active.
Reverse Select,
which is controlled by the drive sequencer, is used to invert
Reference Selected
(Pr
81
) or the
Jog Reference
(Pr
15
).
Jog Select
, which is controlled by the drive sequencer, is used to select the
Jog Reference
(Pr
15
).
This parameter displays the level of the analog signal present at analog input 1 (terminal 2).
This parameter displays the level of the analog signal present at analog input 2 (terminal 5).
90
Digital I/O Read Word
RO
Bin
ND
NC
PT
OL
Ú
0 to 2047
Ö
RFC-A
91
Reference On
RO
Bit
ND
NC
PT
OL
Ú
Off (0) or On (1)
Ö
RFC-A
92
Reverse Select
RO
Bit
ND
NC
PT
OL
Ú
Off (0) or On (1)
Ö
RFC-A
93
Jog Select
RO
Bit
ND
NC
PT
OL
Ú
Off (0) or On (1)
Ö
RFC-A
94
Analog Input 1
RO
Num
ND
NC
PT
FI
OL
Ú
±100.00 %
Ö
RFC-A
95
Analog Input 2
RO
Num
ND
NC
PT
FI
OL
Ú
±100.00 %
Ö
RFC-A