Dinverter
A
User Guide
Issue code: d2au9
7
3
Data
3.1 Dinverter
Table 3–1
Power, voltage and current ratings
150% overload output current for 60 seconds maximum
Max. continuous 100% RMS output current (FLC)
Max. continuous 100% RMS AC input current
Continuous motor shaft power
AC
supply voltage
Number of
AC
supply phases
Model
V
kW
HP
A
A
A
DIN1220025A
1
200 ~ 240
±
10%
0.25
0.33
3.9
1.5
2.3
DIN1220037A
1
200 ~ 240
±
10%
0.37
0.50
5.7
2.3
3.5
DIN1220055A
1
200 ~ 240
±
10%
0.55
0.75
8.4
3.0
4.5
DIN1220075A
1
200 ~ 240
±
10%
0.75
1.00
11.5
4.3
6.5
Motor
requirements
Number of phases: 3
Voltage: 200V to 240V
±
10% (normally delta connected)
Power rating: 0.25kW (0.33HP) to 0.75kW (1HP)
Temperature,
humidity
and cooling
method
Ambient temperature range: –10
°
C to 50
°
C (14
°
F to 122
°
F). Output
current derating may apply at high ambient temperatures.
Storage temperature range: –40
°
C to 50
°
C (–40
°
F to 122
°
F)
Humidity: 85% non-condensing
Cooling method: Natural convection
Ingress
protection
Gland plate not fitted: IP00
Gland plate fitted; cable glands not fitted: IP10
Cable-glands fitted: IP20
Overall
dimensions
These dimensions exclude the mounting brackets.
Height: 140mm (5
1
/
2
in)
Width: 75mm (3 in)
Depth: 192mm (7
1
/
2
in)
Weight
Approximate weight of each model: 1.2kg (2lb 11oz)