The above outputs use the same relay contacts, so the current ratings given above are
applicable for contactor output 3 and 4 combined.
7.3
Fusing
The recommended 24Vdc power supply fuses (F1) is 3A, 50Vdc. This information is
stated on the SPM Power Selector rating label. Ensure that the contactor supply is
appropriately fused as detailed in section 7.2.
7.4
IP rating
The SPM Power Selector Module is rated to IP 20.
5
Contactor 3 & 4 Power Supply
6
Contactor Output 3
7
Contactor 3 & 4 Power Supply
8
Contactor Output 4
Contact Voltage Rating
240 Vac, Installation over-voltage category
Contact maximum current rating
2A AC 240V
4A DC 30V resistive load
0.5A DC 30V inductive load (L/R = 40 ms)
Contact minimum recommended
rating
12V 100mA
Contact Type
Normally Open