SPM Power Selector Module Installation Guide
17
Issue: 2
www.controltechniques.com
S
P
M
E
Para
D
4.5
Operating status LEDs
There are six operating status LEDs on the top cover of the SPM Power Selector
Module. Table 4-3 below provides the key for each LED indicator.
Figure 4-6 Operating status LEDs
Table 4-3 Operating status LED indication
4.6
Power cycling
4.6.1
Power up sequence
The 24V supply to the SPM Power Selector Modules must be applied before the
Unidrive SPM power and control modules are powered up. Failure to do so will cause
the 'POWER SEQ' LED to light on the SPM Power Selector and the Unidrive SPM will
trip.
When the 24V supply is applied to the SPM Power Selector Module, the 'PS ON' LED
will light along with either the 'Master 1' or 'Master 2' LED depending on the state of the
'Master mode select' input.
When the Unidrive SPM power modules are powered up, the 'PM ON' LED will light.
Label
Actual Indication
PS TRIP
24V supply to the SPM Power Selector is not available
POWER SEQ
Incorrect power up sequence
MASTER 1
Master 1 mode selected
MASTER 2
Master 2 mode selected
PM ON
Unidrive SPM Power Module on
PS ON
User 24V is available
5
1
5
12
3
4
CONTR
O
L
PS
TRIP
POWER
SEQ.
1
2
MASTER
PM
ON
PS
ON
Содержание 0471-0144-02