28
SPM Power Selector Module Installation Guide
www.controltechniques.com
Issue: 2
7
Technical data
7.1
SPM Power Selector Module control terminals
7.2
SPM Power Selector Module contactor terminals
The above outputs use the same relay contacts, so the current ratings given above are
applicable for contactor output 1 and 2 combined.
1
+24V external input
Nominal voltage
24Vdc
Minimum voltage
18.4Vdc
Maximum voltage
31.4Vdc
Current drawn
300mA Max
Recommended power supply
24Vdc, 1A
2
0V common
3
Digital output
Voltage
0V with Master 1 selected
24V with Master 2 selected
Maximum output current
16mA
4
5
Master Mode Select
A switch connected between terminals 4 and 5 will enable switching between operating
modes Master 1 and Master 2.
1
Contactor 1 & 2 Power Supply
2
Contactor Output 1
3
Contactor 1 & 2 Power Supply
4
Contactor Output 2
Contact Voltage Rating
240Vac, Installation over-voltage category
Contact maximum current rating
2A AC 240V
4A DC 30V resistive load
0.5A DC 30V inductive load (L/R = 40 ms)
Contact minimum recommended
rating
12V 100mA
Contact Type
Normally Open
Содержание 0471-0144-02