CS1171 Hand-Held Programmer
User's Manual
Control Solutions LLC
Page 26 of 56
Parameter
Description
Batt res
Sets the resistance of the
power wires. It’s used to compensate
the battery display for wiring drop at high current. It is typically
calculated in milliohms:
Batt res value/3485.1485 = Resistance in ohms
Timeout
The length of time before the controller powers down after
inactivity. When set to
0
, the controller will not timeout.
Flash V
Sets the point when the battery voltage reaches the desired low
voltage threshold. When the battery voltage reaches the value set
by
Flash V
, an LED is flashed. The
Flash V
value is in volts.
Full V
Sets the desired point when the battery voltage level is considered
to be fully charged. When using a multi-segmented LED, this
voltage value indicates a full battery on the display.
Full V
is
displayed in Volts.
Cur lim lo
Sets the Current Limit Lower Bound, maximum current allowable
(in Amps). After the Current Limit Upper Bound threshold time is
exceeded (Cur time) the motor controller will limit the maximum
current to this value which protects the motor and supporting
components. Due to tolerances in the drive system, it is
recommended to verify the current limit. See Figure 16.
Figure 16
- Current Parameter Relationships
Warning
Setting the current limit value too high can result in
damage to the motor controller, as well as other
components in the vehicle. Do not set this value
higher than the maximum rated current for the
motors, cables, batteries, and controller.
Содержание CS1171
Страница 1: ...Hand Held Programmer Document Number 000434A Revision B ...