CS1171 Hand-Held Programmer
User's Manual
Control Solutions LLC
Page 36 of 56
Parameter
Description
Fast chgled
A typical charging cycle will go through the following charging
modes in order:
1. Pre-charge,
2. Charge Qualification,
3. Bulk Charge,
4. Top-off Charge, and
5. Float.
The
Fast chgled
on/off
setting determines when to flash the LED.
When set to
On
, flash will occur at the end of Bulk Charge mode.
When set to
Off
, flash will occur at the end of Top-off charge
mode.
Moment key
When set to
On
, the system turns
On
and
Off
with a pushbutton or
momentary contact of the key switch. When set to
Off
, the unit
remains powered up only while the key switch remains closed, and
powers down when the key switch contact is opened.
Timed key
When set to
On
, the unit will not power down immediately when
key switch state indicates power down, but remains on for the
duration defined by
Timeout
. When set to
Off
, the unit powers
down as normal with no delays.
Accel drive
Used to configure throttle for acceleration control, instead of speed
control. When set to
Off
, the controller interprets throttle as a
conventional speed adjustment, where the direction and speed of
the unit is determined by the displacement from center and the
magnitude of the displacement. When set to
On
, a throttle
displacement indicates acceleration to the controller. The unit
accelerates proportional to this displacement, as long as it is
present. Deceleration requires an equal and opposite
displacement.
FWD/REV
input controls direction while
Accel drive
is
On
, which results in a hard stop when toggling direction.
Tht lmt bst
When set to
On
, motor compensation (boost) is limited by the
absolute throttle position.
Acl lmt bst
When set to
On
, motor compensation (boost) is limited by the
acceleration of the throttle position (change in throttle over time).
Soft decel
When set to
On
, negative (decelerating) boost is not applied,
resulting in a soft deceleration.
Qstop hi
Depending on the module configuration quickstop can be wired as
active (+5 V) or passive (GND). In a passive configuration:
When the parameter is
On
, quickstop is asserted when active.
When the parameter is
Off
, quickstop is asserted when the
circuit is closed.