User's Manual
CS1171 Hand-Held Programmer
Page 43 of 56
Control Solutions LLC
Parameter
Description
Keyswitch
Displays in real time whether the controller detects a key switch.
Reverse pin
Displays
On
when the controller detects an active reverse input.
Reverse
Displays
On
when the Reverse input is active.
Chrge time
Displays elapsed time for the current Charging Mode. Time resets
for every Charging Mode change. For Charging Time in hours and
minutes, convert from hexadecimal using
Charge
mode
Indicates current mode of operation while charging. Codes are as
follows:
00
= Pre-charge,
02
= Charge qualification/Bulk charge,
04
= Top-Off charge, and
08
= Float charge.
Figure 17
- Charging Time Conversion