SECTION B: Electric Shower
Installing using a single flowswitch or linking directly to the shower without a flowswitch
Linking directly with a Mira Advance ATL Flex
Extra or Redring Selectronic Premier WP
Re-tighten the gland and connect the electric
shower cables to the terminals marked flowswitch,
as shown.
The flowswitch must be secured using two 15mm
pipe clips. Run the 2 core flowswitch cable to the
control box.
Connecting directly using a flowswitch
Re-tighten the gland and connect the flowswitch
cable to the terminals marked flowswitch.
(It doesn’t matter which way the wires go in).
When using P12 pump with a Mira Advance ATL
Flex Extra you
MUST
move the jumper position
on the circuit board within the shower, as circled
above.
Choose a suitable position for the control box as
near to the pump as possible and mark 4 fixing
holes onto the wall and screw to the wall using
suitable fixings.
Unscrew one of the glands and pass through the
cable from the flowswitch or electric shower.
Fit the supplied filter in the water supply going
to the shower. This must be fitted before the
flowswitch.
The arrow on the filter must point in the direction
the water is flowing.
Install the flowswitch control in the cold water supply
going to the shower.
IMPORTANT: FIT AS CLOSE AS POSSIBLE TO THE
SHOWER TO STOP ANY FALSE READINGS OCCURRING.
Fit in any position or orientation, the arrow on the flow
switch must point in the direction the water flows.
FIT IN AN ACCESSIBLE AREA SO YOU CAN ACCESS
THE FILTER FOR MAINTENANCE OR FOR CLEANING.
IF YOU ARE CONNECTING DIRECTLY TO
AN ELECTRIC SHOWER WITH THE WASTE
PUMP CONNECTION GO TO
POINT 11
NEVER
INSTALL THE CONTROL BOX IN THE DIRECT
SHOWER AREA. REMOVE & DISPOSE OF ANY
CARDBOARD / FOAM TRANSPORT PACKAGING.
Technical Helpline: 0845 402 9924
ENSURE ALL FOAM, PLASTIC AND CARDBOARD
PACKAGING IS FULLY REMOVED
7
8
9
10
11
12
13
14
15
**IMPORTANT**
The jumper on the circuit board needs to be
moved from position
LK2
to position
LK1
, top
left hand corner of the circuit board.
If connecting to a Redring Selectronic WP
shower, please refer to the instructions
supplied with the shower.
P12 PUMP CAN BE LINKED DIRECTLY WITH A MIRA
ADVANCE ATL FLEX EXTRA OR REDRING SELECTRONIC
PREMIER WP,
GO TO POINT 13
.
!
!