SECTION A
Installing the pump

The 22mm flexible pipe supplied must be used from the 22mm outlet gully or waste to the pumps inlet. 

Cut the flexible pipe to the required length. One end of the pipe has a grey solvent weld connector, 
this must be solvent welded to the gully / waste outlet. 
LEAVING EXCESS PIPE COILED BENEATH THE SHOWER TRAY WILL IMPEDE THE PUMPS 
PERFORMANCE.

The maximum length of the flexible pipe between the waste and the pump should be no more than 

2 metres

, with 

as few, or no bends as possible. 

Now connect the pump to the gully / waste 
pipework using the flexible pipework kit supplied, 
ensure both flexible pipes and jubilee clips are 
attached.

FLUSH OUT PIPEWORK BEFORE MAKING FINAL 
CONNECTION TO THE PUMP. 

When level, mark holes and screw directly to the wall 
using suitable fixings. Do not over tighten the screws.
Re-mount the pump to the bracket as previously described 
in Points 2 & 2a.
The pump can be mounted horizontally, as shown, or 
vertically without effecting performance. 

Install the pump so that the outlet side of the pump is slightly higher than the soil pipe connection, this will 
ensure a clean flow away from the pump, and help to keep the pipework clear. 
If you want to use larger outlet pipework a suitable 22 - 40mm connector can be used.

ENSURE ALL PIPEWORK IS SECURELY FIXED TO THE WALL WITH SUITABLE PIPE CLIPS.

 

Do not leave excess pipe colied up beneath the shower tray. 

Fit the pump within 2 metres of the gully or waste. To achieve 

optimum

 pump performance of 

12 litres per minute we recommend the pump be installed no higher than 

350mm 

from the top 

of the shower waste outlet to the underside of the wall plate, as shown in Point 3a . 

The pump can be installed upto a maximum height of 

500mm

 but this 

will

 reduce the pump’s 

overall performance. 

See note 3a above if installing a Gannet top access shower tray.

Shower tray waste

Floor former waste

350mm

Recommended 
Max 500mm

ENSURE ALL PIPEWORK CONNECTIONS ARE 
SECURE TO AVOID ANY AIR BEING 
SUCKED IN WHILST THE PUMP IS OPERATING.

THE PUMP 

MUST NOT

 BE FITTED IN THE 

SHOWERING AREA.

ONCE THE INLET AND OUTLET DIRECTION HAS BEEN 
ESTABLISHED THIS 

SHOULD NOT

 BE CHANGED.

1

1a

3

3a

4

5

6

!

!

!

!

Remove the pump from the wall bracket by undoing 
the bolts on the top bracket, Point 2, and twisting the 
inlet & outlet spigots anti-clockwise so the flanges 
align with the slots in the wall bracket, Point 2a.
The pump body will now slide away from the wall 
bracket.

2

2a

USE THE COLLAR PROVIDED TO PROTECT THE FLEXIBLE 
PIPE WHEN DETAILING THE FLOOR COVERING.

!

IF INSTALLING A 

GANNET

 TRAY INSTALL THE PUMP 

NO HIGHER THAN 

350mm 

FROM THE TRAY OUTLET 

TO THE UNDERSIDE OF THE WALL PLATE.

!

USE THE WASTE / GULLY SUPPLIED. 
CAN BE RETRO FITTED TO OTHER 
MANUFACTURERS COMPATIBLE WASTES.

Содержание P12

Страница 1: ...ED BY ALL POLE DISCONNECTION A QUALIFIED ELECTRICIAN MUST MAKE THE MAINS ELECTRICAL CONNECTION THE PUMP MUST NOT BE FITTED IN THE SHOWERING AREA INSTALLATION GUIDELINES READ BEFORE BEGINNING YOUR INSTALLATION TO ENSURE YOU MAINTAIN P12 AT PEAK PERFORMANCE ANY VARIATION WILL IMPEDE THE PUMP S PERFORMANCE If you are installing an electric shower single flowswitch see sections A B D If you are instal...

Страница 2: ...imensions Housing not fitted A 180mm B 205mm C 270mm B C A ENSURE YOU USE 22mm Flexible Pipe supplied FOR SHOWER TRAYS Kit A UPSW3 is only 30mm in depth 22mm outlet Chrome top flange STANDARD KIT REF 05PP01A LINK PUMP ONLY 05PP01A L FOR FLOOR FORMERS Kit B Use with an Eagle Two shower tray or Prinia shower tray UPSW 4 is only 32mm in depth 22mm outlet Chrome top flange STANDARD KIT REF 05PP01D LIN...

Страница 3: ...nector can be used ENSURE ALL PIPEWORK IS SECURELY FIXED TO THE WALL WITH SUITABLE PIPE CLIPS Do not leave excess pipe colied up beneath the shower tray Fit the pump within 2 metres of the gully or waste To achieve optimum pump performance of 12 litres per minute we recommend the pump be installed no higher than 350mm from the top of the shower waste outlet to the underside of the wall plate as sh...

Страница 4: ...ter in the water supply going to the shower This must be fitted before the flowswitch The arrow on the filter must point in the direction the water is flowing Install the flowswitch control in the cold water supply going to the shower IMPORTANT FIT AS CLOSE AS POSSIBLE TO THE SHOWER TO STOP ANY FALSE READINGS OCCURRING Fit in any position or orientation the arrow on the flow switch must point in t...

Страница 5: ...ur fuse connect the cable to the connections in the control box as follows BROWN to L BLUE to N See WIRING DIAGRAM ABOVE BY PRESSING HOLDING THE TEST BUTTON THE PUMP WILL RUN THE PUMP WILL STOP WHEN THE BUTTON IS RELEASED THERE IS AN EARTH TERMINAL ON THE PUMP SEE POINT 18 Connect the cable from the motor output to the pump and run the rest of the cable to the control box Attach the 2 wires with t...

Страница 6: ...ed in any way The warranty does not include Damage or blockages caused by foreign objects to the pump or flowswitch The cost arising from the removal or reinstatement of tiling etc Damage resulting from the product failing General wear and tear To report a fault contact our Technical Helpline on 0845 402 9924 TECHNICAL SPECIFICATION Self priming 24 volt pump 22mm inlet outlet Outlet from the pump ...

Страница 7: ...aintain the pump at it s peak performance ANY VARIATION WILL IMPEDE THE PUMP S PERFORMANCE Assess your installation prior to installing to ensure the pump control box and flow switch are situated in an accessible area CONTOUR P12 Shower Waste Pump the P12 instructions supplied before beginning your installation to ensure you Technical Helpline 0845 402 9924 ...

Отзывы: