PUMP PERFORMANCE
•
Use the Installation Kits supplied from the waste / gully to the pumps inlet and from the outlet to improve performance. Ensure there is as few, or no bends.
•
The maximum length of the flexible pipe from the waste to the pump should be no more than
2 metres
.
•
The pump is adjustable for use with an electric or mixer shower with a maximum discharge to the waste of 12 litres per minute.
•
Fit the pump within 2 metres of the gully or waste and have the outlet pipework running down to the soil pipe or drain.
•
Fit the pump within 2 metres of the gully or waste. To achieve
optimum
pump performance of 12 litres per minute we recommend the pump be installed no
higher than
350mm
from the top of the shower waste outlet to the underside of the wall plate.
The pump can be installed up to a
maximum of 500mm
but this
will
reduce the pump’s overall performance.
For Gannet top access shower trays the pump should be fitted no higher than 350mm from the tray outlet to the underside of the
.
P12 wall plate.
•
Ideally, the run-off from the pump should fall gradually to the outlet. However, the P12 Pump is capable of providing a head of water in excess of 3.5 metres with
appropriate pipework. For information on how to achieve this, please contact our technical helpline,
0845 402 9924.
WARRANTY
For a period of 5 years from purchase we will repair or replace any faulty
pump, control box or flowswitch which has been correctly installed in an
appropriate application and has not been tampered with or modified in any
way.
The warranty does not include:
• Damage or blockages caused by foreign objects to the pump or
.
flowswitch.
• The cost arising from the removal or reinstatement of tiling etc.
• Damage resulting from the product failing.
• General wear and tear.
To report a fault contact our Technical Helpline on
0845 402 9924
TECHNICAL SPECIFICATION
•
Self priming, 24 volt pump
•
22mm inlet & outlet.
•
Outlet from the pump
must be
22mm. If you want to use larger outlet
pipework a suitable 22mm - 40mm connector can be used.
•
Pump complies to BS7671
•
5 year warranty, see right.
ELECTRICAL CONTROL BOX
•
Power Consumptiom 36 Watts intermittent rating
•
2.5 amp Fast blow fuse
•
IP65 Enclosure for bathrooms
(Never install directly in the showering area).
CONTOUR P12 Pump conforms to the requirements of the EC Low Voltage
Directive 73/23/EEC (amended by 93/68/EEC)
CONTOUR P12 Pump is a Patented Product
Manufactured by H2O Pumps Limited exclusively for Contour Showers.
H2O Pumps Limited and Contour Showers reserve the right to change specifications at
any time without prior notice. Our policy is one of continuous improvement and we reserve
the right to change specifications without prior notice.
The pump housing is moulded to allow ease of fitting
around the inlet and outlet pipework.
There are 3 lugs on the inside edge of the cover,
circled above, which locate onto the wall plate.
The black pad on the inside of the cover is to
elimination vibration and should not be removed.
23
24
SECTION D: Setting up the pump
Continued...
25
Offer the pump cover up to the pump, holding it
slightly above the wall plate, then gently slide the
cover down until it clips positively into position.
Contour Showers, Siddorn Street, Winsford, Cheshire CW7 2BA