PUMP PERFORMANCE

•    

Use the Installation Kits supplied from the waste / gully to the pumps inlet and from the outlet to improve performance. Ensure there is as few, or no bends.

•   

 

The maximum length of the flexible pipe from the waste to the pump should be no more than 

2 metres

.

•   

The pump is adjustable for use with an electric or mixer shower with a maximum discharge to the waste of 12 litres per minute.

•   

Fit the pump within 2 metres of the gully or waste and have the outlet pipework running down to the soil pipe or drain.

•    

Fit the pump within 2 metres of the gully or waste. To achieve 

optimum

 pump performance of 12 litres per minute we recommend the pump be installed no 

      higher than 

350mm

 from the top of the shower waste outlet to the underside of the wall plate.

      The pump can be installed up to a 

maximum of 500mm

 but this 

will

 reduce the pump’s overall performance.  

      

For Gannet top access shower trays the pump should be fitted no higher than 350mm from the tray outlet to the underside of the 

    

 

.

P12 wall plate.

  

•    

Ideally, the run-off from the pump should fall gradually to the outlet. However, the P12 Pump is capable of providing a head of water in excess of 3.5 metres with   

      appropriate pipework. For information on how to achieve this, please contact our technical helpline, 

0845 402 9924. 

WARRANTY

For a period of 5 years from purchase we will repair or replace any faulty 
pump, control box or flowswitch which has been correctly installed in an 
appropriate application and has not been tampered with or modified in any 
way.

The warranty does not include:

•   Damage or blockages caused by foreign objects to the pump or 
     

.

flowswitch.

•   The cost arising from the removal or reinstatement of tiling etc.
•   Damage resulting from the product failing.
•   General wear and tear.

To report a fault contact our Technical Helpline on 

0845 402 9924

TECHNICAL SPECIFICATION

•   

Self priming, 24 volt pump

•   

22mm inlet & outlet. 

•   

Outlet from the pump 

must be

 22mm. If you want to use larger outlet  

      pipework a suitable 22mm - 40mm connector can be used.

•   

Pump complies to BS7671

•   

5 year warranty, see right.

ELECTRICAL CONTROL BOX

•   

Power Consumptiom 36 Watts intermittent rating

•   

2.5 amp Fast blow fuse

•   

IP65 Enclosure for bathrooms  

      

(Never install directly in the showering area).

CONTOUR P12 Pump conforms to the requirements of the EC Low Voltage 
Directive 73/23/EEC (amended by 93/68/EEC)

CONTOUR P12 Pump is a Patented Product

Manufactured by H2O Pumps Limited exclusively for Contour Showers. 

H2O Pumps Limited and Contour Showers reserve the right to change specifications at 
any time without prior notice. Our policy is one of continuous improvement and we reserve 
the right to change specifications without prior notice. 

The pump housing is moulded to allow ease of fitting 
around the inlet and outlet pipework. 

There are 3 lugs on the inside edge of the cover, 
circled above, which locate onto the wall plate. 

The black pad on the inside of the cover is to 
elimination vibration and should not be removed.

23

24

SECTION D: Setting up the pump

Continued... 

25

Offer the pump cover up to the pump, holding it 
slightly above the wall plate, then gently slide the 
cover down until it clips positively into position. 

Contour Showers, Siddorn Street, Winsford, Cheshire CW7 2BA

Содержание P12

Страница 1: ...ED BY ALL POLE DISCONNECTION A QUALIFIED ELECTRICIAN MUST MAKE THE MAINS ELECTRICAL CONNECTION THE PUMP MUST NOT BE FITTED IN THE SHOWERING AREA INSTALLATION GUIDELINES READ BEFORE BEGINNING YOUR INSTALLATION TO ENSURE YOU MAINTAIN P12 AT PEAK PERFORMANCE ANY VARIATION WILL IMPEDE THE PUMP S PERFORMANCE If you are installing an electric shower single flowswitch see sections A B D If you are instal...

Страница 2: ...imensions Housing not fitted A 180mm B 205mm C 270mm B C A ENSURE YOU USE 22mm Flexible Pipe supplied FOR SHOWER TRAYS Kit A UPSW3 is only 30mm in depth 22mm outlet Chrome top flange STANDARD KIT REF 05PP01A LINK PUMP ONLY 05PP01A L FOR FLOOR FORMERS Kit B Use with an Eagle Two shower tray or Prinia shower tray UPSW 4 is only 32mm in depth 22mm outlet Chrome top flange STANDARD KIT REF 05PP01D LIN...

Страница 3: ...nector can be used ENSURE ALL PIPEWORK IS SECURELY FIXED TO THE WALL WITH SUITABLE PIPE CLIPS Do not leave excess pipe colied up beneath the shower tray Fit the pump within 2 metres of the gully or waste To achieve optimum pump performance of 12 litres per minute we recommend the pump be installed no higher than 350mm from the top of the shower waste outlet to the underside of the wall plate as sh...

Страница 4: ...ter in the water supply going to the shower This must be fitted before the flowswitch The arrow on the filter must point in the direction the water is flowing Install the flowswitch control in the cold water supply going to the shower IMPORTANT FIT AS CLOSE AS POSSIBLE TO THE SHOWER TO STOP ANY FALSE READINGS OCCURRING Fit in any position or orientation the arrow on the flow switch must point in t...

Страница 5: ...ur fuse connect the cable to the connections in the control box as follows BROWN to L BLUE to N See WIRING DIAGRAM ABOVE BY PRESSING HOLDING THE TEST BUTTON THE PUMP WILL RUN THE PUMP WILL STOP WHEN THE BUTTON IS RELEASED THERE IS AN EARTH TERMINAL ON THE PUMP SEE POINT 18 Connect the cable from the motor output to the pump and run the rest of the cable to the control box Attach the 2 wires with t...

Страница 6: ...ed in any way The warranty does not include Damage or blockages caused by foreign objects to the pump or flowswitch The cost arising from the removal or reinstatement of tiling etc Damage resulting from the product failing General wear and tear To report a fault contact our Technical Helpline on 0845 402 9924 TECHNICAL SPECIFICATION Self priming 24 volt pump 22mm inlet outlet Outlet from the pump ...

Страница 7: ...aintain the pump at it s peak performance ANY VARIATION WILL IMPEDE THE PUMP S PERFORMANCE Assess your installation prior to installing to ensure the pump control box and flow switch are situated in an accessible area CONTOUR P12 Shower Waste Pump the P12 instructions supplied before beginning your installation to ensure you Technical Helpline 0845 402 9924 ...

Отзывы: