background image

1.

 2 Flowswitches fi tted in the water supply, 

    

 

one in the cold & one in the hot supply.

2.

 Mixer shower

3.

 Waste

4.

 22mm fl exible pipework to pump inlet

5.

 22mm fl exible pipework to outlet

6.

 Contour P12 pump & housing

7.

 To mains supply 230V

8.

 Control box 

1

2

3

4

5

6

7

8

PLEASE NOTE:

An additional fl ow switch is required 
for mixer shower installations.

Fitting Instructions

CONTOUR P12 Shower Waste Pump

Manufactured 

from parts that

are 100% recyclable

Issue 3 - JAN 2017

TYPICAL ELECTRIC SHOWER INSTALLATION

1.

 Flowswitch within the cold water supply

2.

 Electric shower

3.

 Gully

4.

 22mm fl exible pipework to pump inlet

5.

 22mm fl exible pipework to outlet

6.

 Contour P12 pump & housing

7.

 To mains supply 230V

8.

 Control box 

1

2

3

4

5

6

7

8

Technical Helpline: 0845 402 9924

READ

ME!

TYPICAL MIXER SHOWER INSTALLATION

ENSURE

 

YOU USE THE 

22mm Flexible 

Pipe supplied.

A SUITABLE MEANS OF ISOLATION MUST BE PROVIDED. 
THE SUPPLY TERMINALS CAN BE ISOLATED BY ALL-POLE 
DISCONNECTION. A QUALIFIED ELECTRICIAN MUST 
MAKE THE MAINS ELECTRICAL CONNECTION. 

THE PUMP 

MUST NOT

 BE FITTED IN THE 

SHOWERING AREA. 

!

INSTALLATION GUIDELINES

READ BEFORE BEGINNING YOUR 
INSTALLATION TO ENSURE YOU 
MAINTAIN P12 AT PEAK PERFORMANCE. 
ANY VARIATION 

WILL

 IMPEDE THE PUMP’S 

PERFORMANCE.

If you are installing an electric shower & single flowswitch, see 
sections 

A, B & D

If you are installing a mixer shower & two flowswitches, see 
sections 

A, B, C & D

If you are installing an electric shower with a direct link which 
does not require a flowswitch, see sections 

A, B & D.

The 

22mm flexible pipework 

supplied 

must

 be used from 

the gully to the pump’s inlet. 

The maximum length between the waste and the 
pump should be no more than 2 metres.

For 

optimum

 performance of 12 litres per minute we 

recommend the pump be installed no higher than 

350mm

 

from the top of the shower waste outlet to the underside of the 
wall plate. The pump can be installed upto a maximum height 
of 

500mm

 to the underside of the wall plate, but this 

will 

reduce the pump’s overall performance. 

See Note 3a, overleaf, for Gannet shower tray 
installations.

Содержание P12

Страница 1: ...ED BY ALL POLE DISCONNECTION A QUALIFIED ELECTRICIAN MUST MAKE THE MAINS ELECTRICAL CONNECTION THE PUMP MUST NOT BE FITTED IN THE SHOWERING AREA INSTALLATION GUIDELINES READ BEFORE BEGINNING YOUR INSTALLATION TO ENSURE YOU MAINTAIN P12 AT PEAK PERFORMANCE ANY VARIATION WILL IMPEDE THE PUMP S PERFORMANCE If you are installing an electric shower single flowswitch see sections A B D If you are instal...

Страница 2: ...imensions Housing not fitted A 180mm B 205mm C 270mm B C A ENSURE YOU USE 22mm Flexible Pipe supplied FOR SHOWER TRAYS Kit A UPSW3 is only 30mm in depth 22mm outlet Chrome top flange STANDARD KIT REF 05PP01A LINK PUMP ONLY 05PP01A L FOR FLOOR FORMERS Kit B Use with an Eagle Two shower tray or Prinia shower tray UPSW 4 is only 32mm in depth 22mm outlet Chrome top flange STANDARD KIT REF 05PP01D LIN...

Страница 3: ...nector can be used ENSURE ALL PIPEWORK IS SECURELY FIXED TO THE WALL WITH SUITABLE PIPE CLIPS Do not leave excess pipe colied up beneath the shower tray Fit the pump within 2 metres of the gully or waste To achieve optimum pump performance of 12 litres per minute we recommend the pump be installed no higher than 350mm from the top of the shower waste outlet to the underside of the wall plate as sh...

Страница 4: ...ter in the water supply going to the shower This must be fitted before the flowswitch The arrow on the filter must point in the direction the water is flowing Install the flowswitch control in the cold water supply going to the shower IMPORTANT FIT AS CLOSE AS POSSIBLE TO THE SHOWER TO STOP ANY FALSE READINGS OCCURRING Fit in any position or orientation the arrow on the flow switch must point in t...

Страница 5: ...ur fuse connect the cable to the connections in the control box as follows BROWN to L BLUE to N See WIRING DIAGRAM ABOVE BY PRESSING HOLDING THE TEST BUTTON THE PUMP WILL RUN THE PUMP WILL STOP WHEN THE BUTTON IS RELEASED THERE IS AN EARTH TERMINAL ON THE PUMP SEE POINT 18 Connect the cable from the motor output to the pump and run the rest of the cable to the control box Attach the 2 wires with t...

Страница 6: ...ed in any way The warranty does not include Damage or blockages caused by foreign objects to the pump or flowswitch The cost arising from the removal or reinstatement of tiling etc Damage resulting from the product failing General wear and tear To report a fault contact our Technical Helpline on 0845 402 9924 TECHNICAL SPECIFICATION Self priming 24 volt pump 22mm inlet outlet Outlet from the pump ...

Страница 7: ...aintain the pump at it s peak performance ANY VARIATION WILL IMPEDE THE PUMP S PERFORMANCE Assess your installation prior to installing to ensure the pump control box and flow switch are situated in an accessible area CONTOUR P12 Shower Waste Pump the P12 instructions supplied before beginning your installation to ensure you Technical Helpline 0845 402 9924 ...