SECTION C: Mixer Shower

Installing an additional flowswitch

Technical Helpline: 0845 402 9924

REPEAT STEPS 7, 8 & 9 FITTING THE FILTER & 
FLOWSWITCH IN THE HOT WATER SUPPLY, & WIRE IN 
AS ABOVE, SEE ALSO WIRING DIAGRAM, SEE RIGHT.

SECTION D: 

Setting up the pump

P12 pump has 3 LED indicators.    

         

INPUT

 = Flowswitch is connected and water is flowing.

SUPPLY

 = The control box is live and power is present.

PUMP

 = Illuminated when the pump is running.

 

There are 10 adjustable settings for the run on time. 
0 (zero) represents no run on time. Each stepped 
increment is 10 seconds, approximately, upto a 
maximum of 90 seconds. Turn the finger control 
clockwise to increase the run on time.

YOU SHOULD RUN THE SHOWER AS PART OF THE PUMP 
SET-UP PROCESS TO ENSURE THE PUMP RUN ON TIME IS 
SUFFICIENT TO REMOVE ALL WATER FROM THE SHOWER TRAY.

P12 pump has 10 variable speed settings. Using 
this dial P12 can be adjusted to match the 
showers flow rate.

 

TURN ANTI-CLOCKWISE

 = 

Lower speed

TURN CLOCKWISE

 = 

Higher speed

From the control box run a 1.5mm cable to a suitable 
power supply outside the bathroom. 
Electrical supply must be on a spur fuse and fused at 
3 amp. Before connecting the spur fuse connect the 
cable to the connections in the control box as follows:

BROWN

 to L  

BLUE

to N (See WIRING DIAGRAM, ABOVE).

BY PRESSING & HOLDING THE ‘TEST’ BUTTON THE 
PUMP WILL RUN, THE PUMP WILL STOP WHEN 
THE BUTTON IS RELEASED.

THERE IS AN EARTH TERMINAL ON 
THE PUMP, SEE POINT 18.

Connect the cable from the motor output to the 
pump and run the rest of the cable to the control 
box. Attach the 2 wires with the spade type 
connections to the pump terminals.

 

BY SWAPPING THE WIRES AROUND THE PUMP WILL 
CHANGE DIRECTION. USE THE ‘TEST’ BUTTON TO SET 
THE DIRECTION TO MATCH THE INFLOW AND OUTFLOW. 

 

ONCE INSTALLED, THE PUMP’S PIPEWORK 
DIRECTION 

SHOULD NOT

 BE CHANGED.

EXAMPLE:

 SETTING THE SWITCH AT 2 

WOULD BE 20 SECONDS, SETTING AT 4 
WOULD BE 40 SECONDS.

Default setting is ‘5’ to suit a typical electric shower. 
Turn the finger control clockwise to increase the 
pump speed for higher flow showers.
0 = Lowest speed
9 = Highest speed

YOU MUST MAKE THIS ADJUSTMENT TO SUIT 
EACH SPECIFIC INSTALLATION.

ENSURE ALL FOAM, PLASTIC AND CARDBOARD PACKAGING 
IS FULLY REMOVED

16

17

18

19

20

21

22

FOR PUMP SPEED

ADJUSTMENT  

FOR RUN ON ADJUSTMENT

Re-tighten the gland and connect the second flowswitch cable to the 
terminals marked flowswitch. It doesn’t matter which way the wires go in 
and it should be wired in parallel to the same terminal blocks.

!

!

!

!

!

EARTH 

TERMINAL  

PUMP

TERMINALS  

Содержание P12

Страница 1: ...ED BY ALL POLE DISCONNECTION A QUALIFIED ELECTRICIAN MUST MAKE THE MAINS ELECTRICAL CONNECTION THE PUMP MUST NOT BE FITTED IN THE SHOWERING AREA INSTALLATION GUIDELINES READ BEFORE BEGINNING YOUR INSTALLATION TO ENSURE YOU MAINTAIN P12 AT PEAK PERFORMANCE ANY VARIATION WILL IMPEDE THE PUMP S PERFORMANCE If you are installing an electric shower single flowswitch see sections A B D If you are instal...

Страница 2: ...imensions Housing not fitted A 180mm B 205mm C 270mm B C A ENSURE YOU USE 22mm Flexible Pipe supplied FOR SHOWER TRAYS Kit A UPSW3 is only 30mm in depth 22mm outlet Chrome top flange STANDARD KIT REF 05PP01A LINK PUMP ONLY 05PP01A L FOR FLOOR FORMERS Kit B Use with an Eagle Two shower tray or Prinia shower tray UPSW 4 is only 32mm in depth 22mm outlet Chrome top flange STANDARD KIT REF 05PP01D LIN...

Страница 3: ...nector can be used ENSURE ALL PIPEWORK IS SECURELY FIXED TO THE WALL WITH SUITABLE PIPE CLIPS Do not leave excess pipe colied up beneath the shower tray Fit the pump within 2 metres of the gully or waste To achieve optimum pump performance of 12 litres per minute we recommend the pump be installed no higher than 350mm from the top of the shower waste outlet to the underside of the wall plate as sh...

Страница 4: ...ter in the water supply going to the shower This must be fitted before the flowswitch The arrow on the filter must point in the direction the water is flowing Install the flowswitch control in the cold water supply going to the shower IMPORTANT FIT AS CLOSE AS POSSIBLE TO THE SHOWER TO STOP ANY FALSE READINGS OCCURRING Fit in any position or orientation the arrow on the flow switch must point in t...

Страница 5: ...ur fuse connect the cable to the connections in the control box as follows BROWN to L BLUE to N See WIRING DIAGRAM ABOVE BY PRESSING HOLDING THE TEST BUTTON THE PUMP WILL RUN THE PUMP WILL STOP WHEN THE BUTTON IS RELEASED THERE IS AN EARTH TERMINAL ON THE PUMP SEE POINT 18 Connect the cable from the motor output to the pump and run the rest of the cable to the control box Attach the 2 wires with t...

Страница 6: ...ed in any way The warranty does not include Damage or blockages caused by foreign objects to the pump or flowswitch The cost arising from the removal or reinstatement of tiling etc Damage resulting from the product failing General wear and tear To report a fault contact our Technical Helpline on 0845 402 9924 TECHNICAL SPECIFICATION Self priming 24 volt pump 22mm inlet outlet Outlet from the pump ...

Страница 7: ...aintain the pump at it s peak performance ANY VARIATION WILL IMPEDE THE PUMP S PERFORMANCE Assess your installation prior to installing to ensure the pump control box and flow switch are situated in an accessible area CONTOUR P12 Shower Waste Pump the P12 instructions supplied before beginning your installation to ensure you Technical Helpline 0845 402 9924 ...

Отзывы: