Continental Hydraulics Installation Manual
Page 10 of 27
CEM-SA-B
CHI 1020687 01/2016
Parameter Descriptions
LG (Changing the language)
Command
Parameters
Unit
Group
LG
x
x= DE|EN
-
STD
Either English or German can be selected for the displayed texts.
After changing the language settings, the ID button in the menu bar (CHI-PC) must be pressed
(module identification).
MODE (Switching between parameter groups)
Command
Parameters
Unit
Group
MODE
x
x= STD|EXP
-
STD
This command changes the operating mode. Various commands (defined via STD/EXP) are
blanked out in Standard Mode. The commands in Expert Mode have a more significant influence
on system behavior and should accordingly be changed with care. (see page 8)
SENS (monitoring of the modul functions)
Command
Parameters
Unit
Group
SENS
x
x= ON|OFF|AUTO
-
STD
This command is used to activate/deactivate the monitoring functions (4… 20 mA sensors, output
current, signal range and internal failures) of the module.
ON:
All monitoring functions are active. Detected failures can be reset by deactivating the
ENABLE input PIN 8.
OFF:
No monitoring function is active. The READY output will not function in OFF.
AUTO:
Auto reset mode. All monitoring functions are active. If the failure doesn’t exist
anymore, the module automatically resumes to work without deactivating the ENABLE
input PIN 8.
Normally the monitoring functions are always active because otherwise no errors are
detectable via the READY output. Deactivating is possible mainly for troubleshooting.