![Continental Hydraulics CEM-AA-B Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/continental-hydraulics/cem-aa-b/cem-aa-b_installation-manual_2657169009.webp)
Continental Hydraulics Installation Manual
Page 9 of 33
CEM-AA-B
CHI 1020611 01/2016
Parameter List Function AA
Ref Page
Command
Parameter Help / Description
STD
EXP
16
FUNCTION
AA Function mode (AA / A-B / RA) Press ID button after selection
X
X
16
LG
EN EN English
X
X
16
MODE
EXP Standard / Expert mode
X
X
17
SENS
AUTO Malfunction monitoring [ON / OFF /AUTO]
X
X
17
CCMODE
OFF Characteristics linearization [ON / OFF]
X
18
PIN:6
USCALE Function of PIN 6 [USCALE / RAMP]
X
18
USCALE
10000 Output current scale in 0.01%
X
19
LIM
0 Range control input signal in 0.01%
X
20
POL
+ Output polarity (+/-)
X
X
20
AINA
V Input switching, voltage or current [V/C] (Voltage default)
X
20
AIN:A
1000 1000 0 V Input scaling via linear equation
X
22
AA:1
100 Ramptime acceleration A in ms
X
X
22
AA:2
100 Ramptime deceleration A in ms
X
X
22
AA:3
100 Ramptime acceleration B in ms
X
X
22
AA:4
100 Ramptime deceleration B in ms
X
X
26
CC
characteristic curve Free definable characteristic linearization
27
MIN:A
0 Compensation of the Deadband in 0.01%
X
X
27
MIN:B
0 Compensation of the Deadband in 0.01%
X
X
27
MAX:A
10000 Output Scaling in 0.01%
X
X
27
MAX:B
10000 Output Scaling in 0.01%
X
X
27
TRIGGER
200 Trigger point of the MIN function in 0.01%
X
X
29
CURRENT
1000 Rated solenoid current 500…. 2600 mA
X
X
29
DAMPL
500 Dither amplitude in 0.01% of rated current
X
X
29
DFREQ
121 Dither frequency in Hz
X
X
30
PWM
2604 PWM frequency in Hz
X
30
ACC
ON Auto Adjustment of the current loop [OFF / ON]
X
31
PPWM
7 P-Gain of the current loop
X
31
IPWM
40 I-Gain of the current loop
X
MODE