Continental Hydraulics Installation Manual
Page 26 of 33
CEM-AA-B
CHI 1020611 01/2016
CC (Characteristics linearization)
Command
Parameters
Unit
Group
FUNCTION
CC:I X Y
i= -10… 10
x= -10000… 10000
y= -10000… 10000
-
0.01%
0.01%
CCMODE=ON
AA
A-B
A user defined signal characteristic can be set by this function. For activating the parameter
CCMODE has to be switched to ON.
The positive indexes stand for the solenoid A, the negative ones represent the solenoid B. The
curve is calculated according to the equation of the linear interpolation:
y=(x-x1)*(y1-y0)/(x1-
x0)+y1
.
The influence of the linearization can be estimated via the process data on the monitor or on the
oscilloscope.
For the input of the characteristics linearization, the CHI-PC program provides a table and a
graphic data input. The input signal is mapped on to the X-axis and the output signal is mapped
on to the Y-axis.