Continental Hydraulics Installation Manual
Page 32 of 33
CEM-AA-B
CHI 1020611 01/2016
PROCESS DATA (Monitoring)
Command
Description
Unit
FUNCTION
W
C
U
Command value after input scaling
Command value after linearization
Command value to current controller
%
%
%
AA
IA
IB
Output current of solenoid A
Output current of solenoid B
mA
mA
Command
Description
Unit
FUNCTION
WA
CA
UA
WB
CB
UB
Command value after input scaling channel A
Command value after linearization channel A
Command value to current controller channel A
Command value after input scaling channel B
Command value after linearization channel B
Command value to current controller channel B
%
%
%
%
%
%
A-B
IA
IB
Output current of solenoid A
Output current of solenoid B
mA
mA
Command
Description
Unit
FUNCTION
W
C
U
Chosen command value
Command value after ramp function
Command value to current controller
%
%
%
RA
IA
IB
Output current of solenoid A
Output current of solenoid B
mA
mA
The process data are the variable values which can be continuously observed on the monitor or
on the oscilloscope.