![Continental Hydraulics CEM-AA-B Скачать руководство пользователя страница 3](http://html1.mh-extra.com/html/continental-hydraulics/cem-aa-b/cem-aa-b_installation-manual_2657169003.webp)
Continental Hydraulics Installation Manual
Page 3 of 33
CEM-AA-B
CHI 1020611 01/2016
Technical Data - All Function Modes:
Power supply
[VDC]
12… 30 (incl. ripple)
Power consumption max.
[W]
60 (depending on type of solenoid, two solenoids are
active)
External fuse
[A]
3 medium time lag
Reference voltage
[V]
8 (maximum 25 mA)
Digital inputs
[V]
logic 0: < 2
[V]
logic 1: > 10
Input resistance
[kΩ]
25
Digital outputs
[V]
logic 0: < 2
[V]
logic 1: > 12 (50 mA)
Analogue inputs
[V]
±10 / 0… 10; 90 kΩ
[mA]
4...20; 390 Ω
Resolution
[%]
< 0.01
Nominal PWM output current
[mA]
500… 2600; broken wire monitored and short circuit
proof.
PWM frequency
[Hz]
61...2604; adjustable in steps
Sample time (process control)
[ms]
1
Sample time (solenoid current
control)
[ms]
0.125
Interface
USB type B
Virtual COM port driver (CHI-PC):
9600… 57600 Baud (Default = 57600),
1 Stop bit, No parity, No handshake
Housing
Snap On Module EN 50022
Polyamide PA 6.6
Combustibility class V0 (UL94)
Weight
[kg]
0.190
Protection class
IP20
Temperature range
[°C]
-
20… 60
Storage temperature
[°C]
-
20 …70
Humidity
[%]
<95 (not condensing)
Vibration
-
IEC 60068-2-6 (category C)
Connections
USB type B
4 x 4 pol. screw terminals
PE: direct via DIN rail
EMC
EN 61000-6-2: 8/2005
EN 61000-6-4: 6/2007 ; A1:2011