24
W415-1283 / F / 04.30.18
venting installation
E
For optimum performance it is recommended that all horizontal runs have a minimum of
1/4” (6mm) rise per foot/
meter using flexible venting. For safe and proper operation of the appliance, follow the venting instructions exactly.
For clearance to combustible materials from the vent pipe, see "minimum clearance to combustibles" section.
The firestop / vent shield supplied with this appliance must be used when
passing through a combustible wall or floor.
note:
N
5.0 venting installation
!
WARNING
must be sealed using red RTV high temp silicone sealant (W573-0002) (not supplied) or black high temp Mill
Pac (W573-0007) (not supplied).
If using pipe clamps to connect rigid vent components, a minimum of 3 screws must also be used to ensure
the connection cannot slip off.
Do not clamp the flexible vent pipe.
Risk of fire, explosion, or asphyxiation. Improper support of the entire venting system may allow vent to sag
and separate. Use vent run supports and connect vent sections per installation instructions.
Risk of fire, do not allow loose materials or insulation to touch the vent pipe. Remove insulation to allow for the
installation of the attic shield and to maintain clearances to combustibles.
Do not fill the space between the vent pipe and enclosure with any type of material. Do not pack insulation
or combustibles between ceiling firestops. Always maintain specified clearances around venting and firestop
systems. Install wall shields and firestops as specified. Failure to keep insulation or other materials away from
vent pipe may cause fire.
•
•
•
•
•
The appliance exhaust flue collar must be sealed using Mill Pac
. All exhaust and intake vent pipe joints
For safe and proper operation of the appliance, follow the venting instructions exactly.
to connecting the gas and electrical supply to the appliance.
If your appliance is supplied with a remote, ensure the remote receiver is in the
“OFF” position prior
Ensure to unpack all loose materials from inside the firebox prior to connecting the gas and electrical supply
•
•
•
•