REAR EXIT ENCLOSURE
The appliance requires a minimum enclosure height of
41" (104.1cm) for the CB36 OR 44" (111.2cm) for
the CX36-1
. For temperature requirements, the enclosure space around and above the appliance must be left
unobstructed.
CB36 / CX36-1 MAXIMUM REAR VENT CLEARANCES
(EXAMPLE 2: EXTERIOR ALCOVE / DOGHOUSE)
NOTE: The vent shield is telescopic and must be adjusted to shield the full depth of the combustible
wall penetration.
24"
[61cm]
MINIMUM
PLUS RISE*
COMBUSTIBLE
NON-COMBUSTIBLE
1"
[25mm]
3"
[76.2mm]
BRICK
0” (0MM) IF
NON-COMBUSTIBLE
FINISHING IS USED
SUCH AS BRICK
AND STONE.
6 3/8"
[162mm]
41"
[104.1cm]
10"-20"
[254mm-50.8cm]
VENT RUN
11 1/2"
[292mm]
INCOMBUSTIBLE
BRIQUE
0” (0MM) SI LES
MATÉRIAUX SONT
INCOMBUSTIBLES,
COMME DE LA BRIQUE
ET DE LA PIERRE.
24"
[61cm]
MINIMUM
PLUS LA PENTE*
COMBUSTIBLE
1"
[25mm]
3"
[76,2mm]
6 3/8"
[162mm]
41"
[104,1cm]
10"-20"
[254mm-50,8cm]
ÉVENTS
11 1/2"
[292mm]
B
C
D
Ref.
CB36
CX36-1
B
41" (104.1cm)
44" (111.2cm)
C
6 3/8" (162mm)
9 3/8" (238mm)
D
11 1/2" (292mm)
14 1/2" (36.8cm)
* See "venting" section.