5.2 minimum enclosure clearances
COMBUSTIBLE
NON-COMBUSTIBLE
BRICK
0” (0MM) IF
NON-COMBUSTIBLE
FINISHING IS USED
SUCH AS BRICK
AND STONE.
3" [76.2mm]
MINIMUM
1"
[25mm]
50 1/2"
[128.3cm]
54"
[137.2cm]
CEILING
(MIN)
42 5/8"
[108.3cm]
MINIMUM
PLUS RISE*
1"
[25mm]
3"
[76,2mm]
COMBUSTIBLE
INCOMBUSTIBLE
BRIQUE
3"
[76,2mm]
1"
[25mm]
1"
[25mm]
42 5/8"
[108,3cm]
MINIMUM
PLUS LA PENTE*
0” (0MM) SI LES MATÉRIAUX
SONT INCOMBUSTIBLES,
COMME DE LA BRIQUE
ET DE LA PIERRE.
3"
[76.2mm]
3"
[76.2mm]
50 1/2"
[128,3cm]
54"
[137,2cm]
PLAFOND
(MIN)
3" [76,2mm]
MINIMUM
15 5/8”
[39.7cm]
15 5/8”
[39,7cm]
2"
[50.8mm]
2"
[50,8mm]
CEILING
ENCLOSURE
PLAFOND
ENCEINTE
TOP EXIT ENCLOSURE
The appliance requires a minimum enclosure height of 50 1/2" (128.3cm). For temperature requirements, the
enclosure space around and above the appliance must be left unobstructed.
CB36 / CX36-1 TOP VENT
NOTE: The vent shield is telescopic and must be adjusted to shield the full depth of the combustible
wall penetration.
* See "minimum framing dimensions" section for details on reducing vent pipe top clearances.
These parameters also apply to all illustrations in this section.