4. Setup and Status Display
FXA3000 Series
43
11g Only Mode
This setting is available when the unit type is "Access Point" or "Repeater".
When the wireless networking standard is IEEE 802.11n (2.4 GHz) or IEEE 802.11g, this function
prohibits logins by IEEE 802.11b wireless terminals. To use this function, set to "Enable".
Default setting : Disable
Basic Rates
When the unit type is access point or repeater and the wireless networking standard is IEEE 802.11b,
IEEE 802.11g, or IEEE 802.11n (2.4 GHz), you can set the basic rates.
You can select "802.11 (1, 2Mbps)" or "802.11b (1, 2, 5.5, 11Mbps)".
If 11g only mode is enabled, this setting is ignored.
Default setting : 802.11b (1, 2, 5.5, 11 Mbps)
MAC Address Filtering
This setting is available when the unit type is "Access Point" or "Repeater".
The device can allow logins from stations (client terminals) with their wireless MAC addresses registered
in advance and forbid logins from all other stations by enabling the MAC address filtering function.
To enable the function and to edit the list of terminals allowed to log in, click the "Edit List" button and
use the page that is displayed.
Enter the addresses to register in "Registered Addresses". Enter the MAC address as two characters, a
hyphen, two characters, and so on. (Ex: 00-80-4C-00-00-00)
To register only a single address, enter the address only in "Registered Address (Start)" and click the
"Add" button. To set a range of addresses, enter the range in "Registered Address (Start)" and "Registered
Address (End), and click the "Add" button. All the MAC addresses within that range are allowed.
The registered addresses are applied only to the VAP checked with "VAP". Typically there is no problem
leaving VAP1 through VAP4 checked. When applicable VAPs are specified, select the VAPs to check.
The registered MAC addresses are displayed in the "MAC Address Filtering List". When you wish to
delete an entry, click the "DEL" button for the appropriate entry to delete it. Click the "ALL" button to
delete all the entries.
A maximum of 1024 MAC addresses that allow login can be registered.
Default setting : Function: Disable, no entries
WLAN Bridge Between VAP
This setting is available when the unit type is "Access Point".
When set to "Disable", node on this VAP can not communicate (WLAN bridge) with nodes on other
VAPs. When set to "Enable" this is allowed.
Default setting : Enable
WLAN Bridge in This VAP
This setting is available when the unit type is "Access Point".
When set to "Disable", node on this VAP can not communicate (WLAN bridge) with other nodes on this
VAP. When set to "Enable" this is allowed.
Default setting : Enable