4. Setup and Status Display
FXA3000 Series
39
Ethernet
Port Speed
Select the Ethernet port speed. You can select from "Auto-Negotiation", "100Mbps(full duplex)",
"100Mbps(half duplex)", "10Mbps(full duplex)", and "10Mbps(half duplex)".
"Auto-Negotiation" is used normally.
Default setting : Auto-Negotiation
- If one side is set to "Auto" and the other side is set to "100M Full Duplex", the communication mode
for the "Auto" side is recognized as "100M half Duplex". In this case, there may be a high error rate
and normal communication may not be possible. It is recommended that you set the correct
communication mode.
- If one side or both sides are set to "Auto" and the two sides cannot recognize each other, set the
communication mode to the unchanging setting for both sides.
- If port speeds are set incorrectly (for example, one side is set to unchanging 10M and the other side is
set to unchanging 100M), only one device may be able to establish a link or the link may be
repeatedly established and disconnected depending on the communication status. In this case, set the
correct communication mode.
Link Down Condition
When "Link Down Detection" is enabled in the "Advanced Settings" for each VAP, set the link down
judgment condition.
The condition for "Link Status" is when the Ethernet link is disconnected. The condition for "Ping" is
when a specific address can no longer be pinged, in addition to that for "Link Status".
When "Ping" is selected, the settings for "Ping Parameters" appear.
Default setting : Link Status
CAUTION