System Reference
DAI12-4(FIT)GY
57
Table 6.2. Installation Environment Requirements
Parameter
Requirement description
Operating temperature
0 - 50
°
C
Storage temperature
-10 - 60
°
C
Humidity
10 - 90%RH (No condensation)
Floating dust particles
Not to be excessive
Corrosive gases
None
Line-Noise
resistance
Line-noise
AC line/2kV, Signal line/1kV (IEC1000-4-4Level 3, EN61000-4-4Level 3)
Static electricity
resistance
Contact discharge/4kV (IEC1000-4-2Level 2, EN61000-4-2Level 2)
Atmospheric discharge/8kV (IEC1000-4-2Level 3, EN61000-4-2Level 3)
Vibration
resistance
Sweep resistance 10 - 57Hz/semi-amplitude 0.15mm, 57 - 150Hz/2.0G
80minutes each in X, Y, and Z directions (JIS C0040-compliant, IEC68-2-6-
compliant)
Impact resistance
15G, half-sine shock for 11ms in X, Y, and Z directions
(JIS C004-compliant, IEC68-2-27-compliant)