3. External Connection
CNT24-4(PCI)H
33
Connection Method to the External device 1
-Photo coupler isolated Input-
Photo coupler isolated Input Connection
Photo coupler isolated input connection with a rotary encoder or a linear scale open collector output
circuit is shown in the Figure. The maximum input frequency is 500KHz.
For a two-phase input, connect both phase A and phase B. For a single phase input, connect to either
phase A or phase B. If not using the Z phase, this does not need to be connected.
Photo coupler Isolated Input Circuit
220
Ω
Photo coupler
2.2k
Ω
Board
External device
Input pin
+5V
Plus Common
Signal output of
external device
220
Ω
2.2k
Ω
+12V
400
Ω
R
Photo coupler
Plus Common
Input pin
Signal output of
external device
Figure 3.8. Example Connection with the Photo Coupler Isolated Input Circuit
CAUTION
-
The general input signal uses the same circuit structure.
-
To use external power (other than 5V); insert a current limiting resistor at the R position.
The following expression is used to calculate current limiting resistance R with the external power
supply as PV:
<
Rk
Ω <
20
P-5
15
P-5
If P=12, use a 350
Ω
< R < 470
Ω
resistor.
Содержание CNT24-4(PCI)H
Страница 1: ...PC HELPER 4ch 24Bit Up Down Counter Board for PCI CNT24 4 PCI H User s Guide CONTEC CO LTD ...
Страница 7: ...vi CNT24 4 PCI H ...
Страница 15: ...1 Before Using the Product 8 CNT24 4 PCI H ...
Страница 31: ...2 Setup 24 CNT24 4 PCI H 3 Click on the End button to finish condition setting Click on the End Button ...
Страница 35: ...2 Setup 28 CNT24 4 PCI H ...
Страница 53: ...4 Function 46 CNT24 4 PCI H ...