1. Introduction
CNT24-2(USB)GY
9
- Regarding “CE EMC Directive Notice”.
Please see the “Hardware specification” to meet the mentioned standard above.
The ferrite core must be installed in connecting cable so that this product may suit
the above-mentioned standard. And USB connector must be earthed.
Name
Maker
Turn
Quantity
Installation Site
E04SR301334 *
SEIWA
2
1
on USB cable at product side
E04SR200917 *
SEIWA
3
1
on power cable at product side
* Equivalent product can also be used.
Image diagram
Environment
Use this product in the following environment. If used in an unauthorized
environment, the board may overheat, malfunction, or cause a failure.
Operating temperature
0 - 50°C
Operating humidity
10 - 90%RH (No condensation)
Corrosive gases
None
Floating dust particles
Not to be excessive
Ferrite core
Cable
TURN: 1
TURN: 2
TURN: 4